Rated for 70 CFM open-air (78.6 CFM at 0.25 in. w.g.), Utilitech UTL506070 omits a published 0.1-inch sone rating and delivers 8.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 78 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech UTL506070 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 78.6 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 8.1 CFM/W (#338/1,145)
- Static Retention
- 112.3% @ 0.25"
- Motor Draw
- 8.6 W (3.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Utilitech UTL506070 vs. 1,145-Model ENERGY STAR Benchmarks show?
Utilitech UTL506070 (EPA filing PD #4668414) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 78.6 CFM out of 70 CFM (112.3% retention, 24.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Utilitech registers 22 certified models, with SKU UTL506070 (series: Utilitech) (PD #4668414) certified since 2026-07-08. Lighting kit: Yes. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.6 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 75.3 kWh/yr (~$12.05/yr) continuously. Closest competing matches include Delta VFB080B4A1-LVDC (80.0 CFM) and Delta 80F-LED (80.0 CFM).
How do flex elbows choke Utilitech UTL506070 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Utilitech UTL506070 moving full rated CFM.
Does Utilitech UTL506070 meet residential exhaust fan code specs?
Inspect Utilitech UTL506070 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Utilitech (22 models) | ENERGY STAR Certified Partner |
| Model Number & Series | UTL506070 / Utilitech | PD ID 4668414 (Qualified 2026-07-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (78.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Utilitech UTL506070 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Utilitech UTL506070 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 78 sq ft | 1 CFM/sq ft @ 78.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 69 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 28 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.1 kWh/yr (~$0.50/yr) | 8.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 75.3 kWh/yr (~$12.05/yr) | 8.6 W x 8,760 hrs / 1,000 |
Which competing models share Utilitech UTL506070 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta VFB080B4A1-LVDC | 80 / 61.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Delta 80F-LED | 80 / 61.5 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-BN | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-MB | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
How much airflow margin does Utilitech UTL506070 give your bath?
Run a quick local room-volume check for Utilitech UTL506070 by entering square footage and ceiling height to spot under-vented steam risks early.
Where should contractors skip Utilitech UTL506070 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Utilitech UTL506070 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 28 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 78 sq ft with 8-ft ceilings (69 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Utilitech UTL506070?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Utilitech UTL506070.
How much power does Utilitech UTL506070 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Utilitech UTL506070 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Utilitech UTL506070 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech UTL506070's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Utilitech UTL506070?
Utilitech UTL506070 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Utilitech UTL506070's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech UTL506070's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Utilitech UTL506070 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Utilitech UTL506070 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Utilitech UTL506070?
Rule out Utilitech UTL506070 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Utilitech UTL506070 capacity?
Because static drag at 0.25 in. w.g. lowers Utilitech UTL506070 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Utilitech UTL506070 compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Utilitech UTL506070 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)