Rated for 70 CFM open-air (79 CFM at 0.25 in. w.g.), Revent RVS506070 omits a published 0.1-inch sone rating and delivers 8.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 79 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVS506070 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 79 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 8.2 CFM/W (#330/1,145)
- Static Retention
- 112.9% @ 0.25"
- Motor Draw
- 8.5 W (3.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Revent RVS506070 vs. 1,145-Model ENERGY STAR Benchmarks show?
Revent RVS506070 (EPA filing PD #4610255) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 79 CFM out of 70 CFM (112.9% retention, 25.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Revent's 40-unit lineup, RVS506070 (series: ReVent) carries PD #4610255 dating to 2026-04-22. Lighting kit: No. At 8.2 CFM/W (#330 of 1,145, top 29.4% of 1,145 rated models, more efficient than 70.6% of rated models, 3.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.5 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 74.5 kWh/yr (~$11.92/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Delta VFB080B4A1-LVDC (80.0 CFM).
How do flex elbows choke Revent RVS506070 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Revent RVS506070 moving full rated CFM.
Does Revent RVS506070 meet residential exhaust fan code specs?
Inspect Revent RVS506070 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Revent (40 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RVS506070 / ReVent | PD ID 4610255 (Qualified 2026-04-22) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (79 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Revent RVS506070 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Revent RVS506070 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 79 sq ft | 1 CFM/sq ft @ 79 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 29 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.1 kWh/yr (~$0.50/yr) | 8.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 74.5 kWh/yr (~$11.92/yr) | 8.5 W x 8,760 hrs / 1,000 |
Which competing models share Revent RVS506070 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7142-70-L | 70 / 55.5 CFM | 1.5 sones | 7.2 CFM/W | 3 in. diameter |
| Delta VFB080B4A1-LVDC | 80 / 61.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Delta 80F-LED | 80 / 61.5 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-BN | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
How much airflow margin does Revent RVS506070 give your bath?
Run a quick local room-volume check for Revent RVS506070 by entering square footage and ceiling height to spot under-vented steam risks early.
When does Revent RVS506070 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Revent RVS506070.
Limitations & Who Should Skip
- Steam or walk-in tub room > 29 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 79 sq ft with 8-ft ceilings (70 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Revent RVS506070?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Revent RVS506070.
How much airflow does Revent RVS506070 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Revent RVS506070 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Revent RVS506070 disturb adjacent bedrooms during night use?
Acoustic measurement places Revent RVS506070 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Revent RVS506070 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Revent RVS506070 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Revent RVS506070 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVS506070's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Revent RVS506070?
Revent RVS506070 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Revent RVS506070's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVS506070's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Revent RVS506070 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Revent RVS506070 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Revent RVS506070?
Do not force Revent RVS506070 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)