Revent RVL506070 Exhaust Fan Specifications

ENERGY STAR PD #4587272 · Bathroom/Utility Room · Qualified 2026-04-22
Verified Specification Summary

Rated for 70 CFM open-air (78.6 CFM at 0.25 in. w.g.), Revent RVL506070 omits a published 0.1-inch sone rating and delivers 8.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 78 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVL506070 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 78.6 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.1 CFM/W (#338/1,145)
Static Retention
112.3% @ 0.25"
Motor Draw
8.6 W (3.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVL506070 vs. 1,145-Model ENERGY STAR Benchmarks show?

Revent RVL506070 (EPA filing PD #4587272) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 78.6 CFM out of 70 CFM (112.3% retention, 24.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Revent's 40-unit lineup, RVL506070 (series: ReVent) carries PD #4587272 dating to 2026-04-22. Lighting kit: Yes. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.6 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 75.3 kWh/yr (~$12.05/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Delta VFB080B4A1-LVDC (80.0 CFM).

How do flex elbows choke Revent RVL506070 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Revent RVL506070 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Revent RVL506070 meet residential exhaust fan code specs?

Inspect Revent RVL506070 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVL506070 / ReVent PD ID 4587272 (Qualified 2026-04-22)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (78.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Revent RVL506070 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Revent RVL506070 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Revent RVL506070
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 78 sq ft1 CFM/sq ft @ 78.6 CFM
Tall Bath (9-ft Ceiling)Up to 69 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 28 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.1 kWh/yr (~$0.50/yr)8.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.275.3 kWh/yr (~$12.05/yr)8.6 W x 8,760 hrs / 1,000

Which competing models share Revent RVL506070 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7142-70-L 70 / 55.5 CFM 1.5 sones 7.2 CFM/W 3 in. diameter
Delta VFB080B4A1-LVDC 80 / 61.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta 80F-LED 80 / 61.5 CFM 1.5 sones 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ 80 / 62.9 CFM 1.5 sones 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ-BN 80 / 62.9 CFM 1.5 sones 7.2 CFM/W 4 in. diameter

How much airflow margin does Revent RVL506070 give your bath?

Run a quick local room-volume check for Revent RVL506070 by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Revent RVL506070 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Revent RVL506070 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 28 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 78 sq ft with 8-ft ceilings (69 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Revent RVL506070?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Revent RVL506070.

How does Revent RVL506070 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Revent RVL506070 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Revent RVL506070?

Rule out Revent RVL506070 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Revent RVL506070 capacity?

Because static drag at 0.25 in. w.g. lowers Revent RVL506070 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Revent RVL506070 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Revent RVL506070 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Revent RVL506070 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Revent RVL506070 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Revent RVL506070 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVL506070's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVL506070?

Revent RVL506070 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVL506070's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVL506070's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories