Certified by EPA ENERGY STAR, Delta SLM70D2 delivers 70 CFM free-air (60.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 7.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 60 sq ft (8-ft height) or 53 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM70D2 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 60.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.0 CFM/W (#420/1,145)
- Static Retention
- 86.4% @ 0.25"
- Motor Draw
- 10.0 W (3.6 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Delta SLM70D2 vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta SLM70D2 (EPA filing PD #4515600) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.5 CFM out of 70 CFM (86.4% retention, 1.3 pts lower retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4515600 verifies SLM70D2 (series: BreezSlim) under Delta (121 listed models, qualified 2025-09-05). Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.0 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 87.6 kWh/yr (~$14.02/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Revent RVSX50 (50.0 CFM).
Why does rigid 3 in. diameter ducting protect Delta SLM70D2 airflow?
Connecting Delta SLM70D2 through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Delta SLM70D2 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SLM70D2 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SLM70D2 / BreezSlim | PD ID 4515600 (Qualified 2025-09-05) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (60.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Delta SLM70D2?
Calculated coverage metrics translate Delta SLM70D2 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.6 kWh/yr (~$0.58/yr) | 10.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 87.6 kWh/yr (~$14.02/yr) | 10.0 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Delta SLM70D2?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7142-70-L | 70 / 55.5 CFM | 1.5 sones | 7.2 CFM/W | 3 in. diameter |
| Revent RVSX50 | 50 / 51.2 CFM | 1.5 sones | 7.3 CFM/W | 4 in. diameter |
| Delta 80F-LED | 80 / 61.5 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
| Delta 80RLED-ADJ-BN | 80 / 62.9 CFM | 1.5 sones | 7.2 CFM/W | 4 in. diameter |
Does Delta SLM70D2 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SLM70D2 percentage capacity without sending data.
When does Delta SLM70D2 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta SLM70D2.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 60.5 CFM net static output
- Target scenario: Collar pairs with 3 in. diameter duct straight outdoors
Which homeowner questions come up most for Delta SLM70D2?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SLM70D2.
Does running Delta SLM70D2 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Delta SLM70D2 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Delta SLM70D2 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM70D2's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SLM70D2?
Delta SLM70D2 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SLM70D2's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM70D2's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Delta SLM70D2 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta SLM70D2 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Delta SLM70D2?
Do not force Delta SLM70D2 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Delta SLM70D2 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Delta SLM70D2 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.
Will Delta SLM70D2 disturb adjacent bedrooms during night use?
Acoustic measurement places Delta SLM70D2 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)