Skip to main content
Grant Estimator

Delta SLM70D Exhaust Fan Specifications

ENERGY STAR PD #2310190 · Bathroom/Utility Room · Qualified 2018-01-19
Verified Specification Summary

Certified by EPA ENERGY STAR, Delta SLM70D delivers 70 CFM free-air (56.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 7.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 56 sq ft (8-ft height) or 49 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SLM70D Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 56.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.0 CFM/W (#420/1,145)
Static Retention
80.1% @ 0.25"
Motor Draw
10.0 W (3.6 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SLM70D vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SLM70D (EPA filing PD #2310190) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 56.1 CFM at 0.25 in. w.g. (80.1% retention, 7.6 pts lower retention than the 87.7% median), making smooth 3 in. diameter rigid metal runs critical. Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta SLM70D (series: BreezSlim) under PD #2310190 (121 models registered, 2018-01-19). Lighting kit: No. At 7.0 CFM/W (#420 of 1,145, top 37.4% of 1,145 rated models, more efficient than 62.6% of rated models, 2.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.0 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 87.6 kWh/yr (~$14.02/yr) continuously. Closest competing matches include Utilitech 7142-70-L (70.0 CFM) and Revent RVSX50 (50.0 CFM).

Why does rigid 3 in. diameter ducting protect Delta SLM70D airflow?

Connecting Delta SLM70D through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Delta SLM70D performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SLM70D lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SLM70D / BreezSlim PD ID 2310190 (Qualified 2018-01-19)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (56.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Delta SLM70D?

Calculated coverage metrics translate Delta SLM70D airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Delta SLM70D
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 56 sq ft1 CFM/sq ft @ 56.1 CFM
Tall Bath (9-ft Ceiling)Up to 49 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.6 kWh/yr (~$0.58/yr)10.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.287.6 kWh/yr (~$14.02/yr)10.0 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Delta SLM70D?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7142-70-L 70 / 55.5 CFM 1.5 sones 7.2 CFM/W 3 in. diameter
Revent RVSX50 50 / 51.2 CFM 1.5 sones 7.3 CFM/W 4 in. diameter
Delta 80F-LED 80 / 61.5 CFM 1.5 sones 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ 80 / 62.9 CFM 1.5 sones 7.2 CFM/W 4 in. diameter
Delta 80RLED-ADJ-BN 80 / 62.9 CFM 1.5 sones 7.2 CFM/W 4 in. diameter

Does Delta SLM70D match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SLM70D percentage capacity without sending data.

Who should not install Delta SLM70D in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta SLM70D for residential use.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 56.1 CFM net static output
  • Primary match: Collar pairs with 3 in. diameter duct straight outdoors

Which homeowner questions come up most for Delta SLM70D?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SLM70D.

Does Delta SLM70D satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta SLM70D clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Delta SLM70D undersized or poorly matched for a bath renovation?

Skip Delta SLM70D if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Delta SLM70D CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta SLM70D registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.

How does Delta SLM70D sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Delta SLM70D produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Delta SLM70D?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Delta SLM70D pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SLM70D's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SLM70D?

Delta SLM70D features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SLM70D's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SLM70D's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories