Skip to main content
Grant Estimator

Broan XB110=XB000HwithXB110F Exhaust Fan Specifications

ENERGY STAR PD #2333770 · Bathroom/Utility Room · Qualified 2019-02-15
Verified Specification Summary

Rated for 110 CFM open-air (110.2 CFM at 0.25 in. w.g.), Broan XB110=XB000HwithXB110F registers #10 of 607 in quietness (0.1 sones) and delivers 14.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 110 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan XB110=XB000HwithXB110F Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 110.2 CFM
Noise @ 0.1"
0.1 sones (#10/607)
Efficacy Rank
14.3 CFM/W (#34/1,145)
Static Retention
100.2% @ 0.25"
Motor Draw
7.7 W (2.8 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan XB110=XB000HwithXB110F vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.1 sones (#10 of 607 rated models, quietest 2.8% of 607 rated models, quieter than 97.2% of rated models, 0.90 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.2 CFM out of 110 CFM (100.2% retention, 12.5 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Broan's 207-unit lineup, XB110=XB000HwithXB110F (series: ULTRA GREEN) carries PD #2333770 dating to 2019-02-15. Lighting kit: No. At 14.3 CFM/W (#34 of 1,145, top 3.1% of 1,145 rated models, more efficient than 96.9% of rated models, 9.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.7 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 67.5 kWh/yr (~$10.80/yr) continuously. Closest competing matches include Pennbarry ZQ110 6" (110.0 CFM) and Broan (Canada) XB110L1 (110.0 CFM).

How does Broan XB110=XB000HwithXB110F acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan XB110=XB000HwithXB110F (0.1 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.1 sone: 0.1 sones (3rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.1 sone: 0.1 sones (P3)

How do flex elbows choke Broan XB110=XB000HwithXB110F at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Broan XB110=XB000HwithXB110F moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Broan XB110=XB000HwithXB110F meet residential exhaust fan code specs?

Inspect Broan XB110=XB000HwithXB110F mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series XB110=XB000HwithXB110F / ULTRA GREEN PD ID 2333770 (Qualified 2019-02-15)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (110.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.1 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Broan XB110=XB000HwithXB110F airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan XB110=XB000HwithXB110F tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan XB110=XB000HwithXB110F
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 110 sq ft1 CFM/sq ft @ 110.2 CFM
Tall Bath (9-ft Ceiling)Up to 97 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 60 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.8 kWh/yr (~$0.45/yr)7.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.267.5 kWh/yr (~$10.80/yr)7.7 W x 8,760 hrs / 1,000

Which competing models share Broan XB110=XB000HwithXB110F airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Pennbarry ZQ110 6" 110 / N/A CFM 0.3 sones (+0.20) 13.1 CFM/W 8 in. diameter
Broan (Canada) XB110L1 110 / 110.3 CFM 0.3 sones (+0.20) 12.6 CFM/W 6 in. diameter
Broan XB110H 110 / 110.2 CFM 0.1 sones (Same) 14.3 CFM/W 6 in. diameter
Broan XB110 110 / 110.2 CFM 0.3 sones (+0.20) 14.3 CFM/W 6 in. diameter
Broan XB110HL1 110 / 110.3 CFM 0.3 sones (+0.20) 12.6 CFM/W 6 in. diameter

How much airflow margin does Broan XB110=XB000HwithXB110F give your bath?

Run a quick local room-volume check for Broan XB110=XB000HwithXB110F by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Broan XB110=XB000HwithXB110F on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan XB110=XB000HwithXB110F carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 60 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 110 sq ft with 8-ft ceilings (97 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about Broan XB110=XB000HwithXB110F?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan XB110=XB000HwithXB110F.

Will long attic ducting choke Broan XB110=XB000HwithXB110F capacity?

Because static drag at 0.25 in. w.g. lowers Broan XB110=XB000HwithXB110F from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Broan XB110=XB000HwithXB110F compared with a standard 3.0 sone builder fan?

Tested at 0.1 sones, Broan XB110=XB000HwithXB110F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Broan XB110=XB000HwithXB110F consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan XB110=XB000HwithXB110F draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan XB110=XB000HwithXB110F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan XB110=XB000HwithXB110F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan XB110=XB000HwithXB110F?

Broan XB110=XB000HwithXB110F features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan XB110=XB000HwithXB110F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan XB110=XB000HwithXB110F's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Broan XB110=XB000HwithXB110F score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan XB110=XB000HwithXB110F delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Broan XB110=XB000HwithXB110F?

Rule out Broan XB110=XB000HwithXB110F when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories