Rated for 110 CFM open-air (110.2 CFM at 0.25 in. w.g.), Broan XB110=XB000HwithXB110F registers #10 of 607 in quietness (0.1 sones) and delivers 14.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 110 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan XB110=XB000HwithXB110F Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 110.2 CFM
- Noise @ 0.1"
- 0.1 sones (#10/607)
- Efficacy Rank
- 14.3 CFM/W (#34/1,145)
- Static Retention
- 100.2% @ 0.25"
- Motor Draw
- 7.7 W (2.8 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan XB110=XB000HwithXB110F vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.1 sones (#10 of 607 rated models, quietest 2.8% of 607 rated models, quieter than 97.2% of rated models, 0.90 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.2 CFM out of 110 CFM (100.2% retention, 12.5 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Broan's 207-unit lineup, XB110=XB000HwithXB110F (series: ULTRA GREEN) carries PD #2333770 dating to 2019-02-15. Lighting kit: No. At 14.3 CFM/W (#34 of 1,145, top 3.1% of 1,145 rated models, more efficient than 96.9% of rated models, 9.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.7 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 67.5 kWh/yr (~$10.80/yr) continuously. Closest competing matches include Pennbarry ZQ110 6" (110.0 CFM) and Broan (Canada) XB110L1 (110.0 CFM).
How does Broan XB110=XB000HwithXB110F acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan XB110=XB000HwithXB110F (0.1 sones).
How do flex elbows choke Broan XB110=XB000HwithXB110F at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Broan XB110=XB000HwithXB110F moving full rated CFM.
Does Broan XB110=XB000HwithXB110F meet residential exhaust fan code specs?
Inspect Broan XB110=XB000HwithXB110F mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | XB110=XB000HwithXB110F / ULTRA GREEN | PD ID 2333770 (Qualified 2019-02-15) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (110.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.1 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan XB110=XB000HwithXB110F airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan XB110=XB000HwithXB110F tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 110 sq ft | 1 CFM/sq ft @ 110.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 97 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 60 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.8 kWh/yr (~$0.45/yr) | 7.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 67.5 kWh/yr (~$10.80/yr) | 7.7 W x 8,760 hrs / 1,000 |
Which competing models share Broan XB110=XB000HwithXB110F airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Pennbarry ZQ110 6" | 110 / N/A CFM | 0.3 sones (+0.20) | 13.1 CFM/W | 8 in. diameter |
| Broan (Canada) XB110L1 | 110 / 110.3 CFM | 0.3 sones (+0.20) | 12.6 CFM/W | 6 in. diameter |
| Broan XB110H | 110 / 110.2 CFM | 0.1 sones (Same) | 14.3 CFM/W | 6 in. diameter |
| Broan XB110 | 110 / 110.2 CFM | 0.3 sones (+0.20) | 14.3 CFM/W | 6 in. diameter |
| Broan XB110HL1 | 110 / 110.3 CFM | 0.3 sones (+0.20) | 12.6 CFM/W | 6 in. diameter |
How much airflow margin does Broan XB110=XB000HwithXB110F give your bath?
Run a quick local room-volume check for Broan XB110=XB000HwithXB110F by entering square footage and ceiling height to spot under-vented steam risks early.
Where should contractors skip Broan XB110=XB000HwithXB110F on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan XB110=XB000HwithXB110F carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 60 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 110 sq ft with 8-ft ceilings (97 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Broan XB110=XB000HwithXB110F?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan XB110=XB000HwithXB110F.
Will long attic ducting choke Broan XB110=XB000HwithXB110F capacity?
Because static drag at 0.25 in. w.g. lowers Broan XB110=XB000HwithXB110F from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Broan XB110=XB000HwithXB110F compared with a standard 3.0 sone builder fan?
Tested at 0.1 sones, Broan XB110=XB000HwithXB110F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Broan XB110=XB000HwithXB110F consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Broan XB110=XB000HwithXB110F draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Broan XB110=XB000HwithXB110F pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan XB110=XB000HwithXB110F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan XB110=XB000HwithXB110F?
Broan XB110=XB000HwithXB110F features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan XB110=XB000HwithXB110F's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan XB110=XB000HwithXB110F's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Broan XB110=XB000HwithXB110F score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan XB110=XB000HwithXB110F delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Broan XB110=XB000HwithXB110F?
Rule out Broan XB110=XB000HwithXB110F when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)