Tested under HVI protocols, the Broan XB110 exhaust unit achieves 110 CFM at 0.1 in. w.g. (110.2 CFM at 0.25 in. w.g.), registers #24 of 607 in quietness (0.3 sones) and delivers 14.3 CFM/W efficacy, covering standard baths up to 110 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan XB110 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 110.2 CFM
- Noise @ 0.1"
- 0.3 sones (#24/607)
- Efficacy Rank
- 14.3 CFM/W (#34/1,145)
- Static Retention
- 100.2% @ 0.25"
- Motor Draw
- 7.7 W (2.8 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan XB110 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.2 CFM out of 110 CFM (100.2% retention, 12.5 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #2249264 verifies XB110 (series: Ultra) under Broan (207 listed models, qualified 2015-08-01). Lighting kit: No. At 14.3 CFM/W (#34 of 1,145, top 3.1% of 1,145 rated models, more efficient than 96.9% of rated models, 9.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.7 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 67.5 kWh/yr (~$10.80/yr) continuously. Closest competing matches include Pennbarry ZQ110 6" (110.0 CFM) and Broan (Canada) XB110L1 (110.0 CFM).
Where do Broan XB110 sones rank across EPA ENERGY STAR fans?
Comparing Broan XB110 (0.3 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Broan XB110 CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan XB110, preventing premature peeling paint and mold growth.
How does Broan XB110 measure up on airflow and noise ratings?
Each row below breaks down Broan XB110 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | XB110 / Ultra | PD ID 2249264 (Qualified 2015-08-01) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (110.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.3 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Broan XB110 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 110 sq ft | 1 CFM/sq ft @ 110.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 97 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 60 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.8 kWh/yr (~$0.45/yr) | 7.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 67.5 kWh/yr (~$10.80/yr) | 7.7 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan XB110?
Compare Broan XB110 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Pennbarry ZQ110 6" | 110 / N/A CFM | 0.3 sones (Same) | 13.1 CFM/W | 8 in. diameter |
| Broan (Canada) XB110L1 | 110 / 110.3 CFM | 0.3 sones (Same) | 12.6 CFM/W | 6 in. diameter |
| Broan XB110=XB000HwithXB110F | 110 / 110.2 CFM | 0.1 sones (-0.20) | 14.3 CFM/W | 6 in. diameter |
| Broan XB110H | 110 / 110.2 CFM | 0.1 sones (-0.20) | 14.3 CFM/W | 6 in. diameter |
| Broan XB110HL1 | 110 / 110.3 CFM | 0.3 sones (Same) | 12.6 CFM/W | 6 in. diameter |
Can you size Broan XB110 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan XB110 verified capacity.
Which bath layouts should avoid specifying Broan XB110?
Match Broan XB110 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 110.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 0.3 sones up to 110 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Broan XB110?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan XB110.
What does Broan XB110 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Broan XB110 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Broan XB110 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan XB110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan XB110?
Broan XB110 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan XB110's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan XB110's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Broan XB110 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan XB110 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Broan XB110 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan XB110.
What happens to Broan XB110 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Broan XB110 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Broan XB110 sit on acoustic comfort for senior homeowners?
Measuring 0.3 sones, Broan XB110 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)