Tested under HVI protocols, the Kaze Appliance SEP120 exhaust unit achieves 120 CFM at 0.1 in. w.g. (94.2 CFM at 0.25 in. w.g.), registers #24 of 607 in quietness (0.3 sones) and delivers 4.2 CFM/W efficacy, covering standard baths up to 94 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Kaze Appliance SEP120 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 120 / 94.2 CFM
- Noise @ 0.1"
- 0.3 sones (#24/607)
- Efficacy Rank
- 4.2 CFM/W (#774/1,145)
- Static Retention
- 78.5% @ 0.25"
- Motor Draw
- 28.6 W (10.4 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Kaze Appliance SEP120 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.3 sones (#24 of 607 rated models, quietest 8.1% of 607 rated models, quieter than 91.9% of rated models, 0.70 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 120 CFM open-air to 94.2 CFM at 0.25 in. w.g. (78.5% retention, 9.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Manufacturer coverage places SEP120 (series: SEP) (PD #2524269) among 4 Kaze Appliance entries qualified through 2023-06-23. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.6 watts, about 10.4 kWh/yr (~$1.66/yr at $0.16/kWh) for 1 hr/day shower timers or 250.5 kWh/yr (~$40.08/yr) continuously. Closest competing matches include S&P PC110XP (120.0 CFM) and Broan QTXEG110 (110.0 CFM).
Where do Kaze Appliance SEP120 sones rank across EPA ENERGY STAR fans?
Comparing Kaze Appliance SEP120 (0.3 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Kaze Appliance SEP120 CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Kaze Appliance SEP120, preventing premature peeling paint and mold growth.
How does Kaze Appliance SEP120 measure up on airflow and noise ratings?
Each row below breaks down Kaze Appliance SEP120 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Kaze Appliance (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SEP120 / SEP | PD ID 2524269 (Qualified 2023-06-23) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (94.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.3 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Kaze Appliance SEP120 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 94 sq ft | 1 CFM/sq ft @ 94.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 44 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.4 kWh/yr (~$1.66/yr) | 28.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 250.5 kWh/yr (~$40.08/yr) | 28.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Kaze Appliance SEP120?
Compare Kaze Appliance SEP120 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| S&P PC110XP | 120 / 94.2 CFM | 0.3 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Broan QTXEG110 | 110 / 85.6 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |
| Broan QTXEG110 = QTXEGH with QTXEG110F | 110 / 85.6 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |
| Broan QTXEG110S | 110 / 85.6 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |
| Broan QTXEG110S = QTXEGSH with QTXEG110SF | 110 / 85.6 CFM | 0.4 sones (+0.10) | 4.7 CFM/W | 6 in. diameter |
Can you size Kaze Appliance SEP120 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Kaze Appliance SEP120 verified capacity.
Which bath layouts should avoid specifying Kaze Appliance SEP120?
Match Kaze Appliance SEP120 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 94.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 0.3 sones up to 94 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Kaze Appliance SEP120?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Kaze Appliance SEP120.
What bathroom square footage can Kaze Appliance SEP120 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Kaze Appliance SEP120 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Kaze Appliance SEP120 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Kaze Appliance SEP120.
What happens to Kaze Appliance SEP120 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Kaze Appliance SEP120 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Kaze Appliance SEP120 sit on acoustic comfort for senior homeowners?
Measuring 0.3 sones, Kaze Appliance SEP120 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Kaze Appliance SEP120 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Kaze Appliance SEP120 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Kaze Appliance SEP120 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Kaze Appliance SEP120's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Kaze Appliance SEP120?
Kaze Appliance SEP120 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Kaze Appliance SEP120's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Kaze Appliance SEP120's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)