Broan QTXEG110X Exhaust Fan Specifications

ENERGY STAR PD #4008360 · Bathroom/Utility Room · Qualified 2025-02-07
Verified Specification Summary

Certified by EPA ENERGY STAR, Broan QTXEG110X delivers 110 CFM free-air (85.6 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 4.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 85 sq ft (8-ft height) or 76 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan QTXEG110X Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 85.6 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
77.8% @ 0.25"
Motor Draw
23.4 W (8.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan QTXEG110X vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 85.6 CFM at 0.25 in. w.g. (77.8% retention, 9.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #4008360 verifies QTXEG110X (series: QT SERIES) under Broan (207 listed models, qualified 2025-02-07). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 23.4 watts, about 8.5 kWh/yr (~$1.36/yr at $0.16/kWh) for 1 hr/day shower timers or 205.0 kWh/yr (~$32.80/yr) continuously. Closest competing matches include Nutone RN110 (110.0 CFM) and Kaze Appliance SEP120 (120.0 CFM).

How noisy is Broan QTXEG110X compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan QTXEG110X measures 0.4 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

Why does rigid 6 in. diameter ducting protect Broan QTXEG110X airflow?

Connecting Broan QTXEG110X through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Broan QTXEG110X performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan QTXEG110X lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series QTXEG110X / QT SERIES PD ID 4008360 (Qualified 2025-02-07)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (85.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Broan QTXEG110X?

Calculated coverage metrics translate Broan QTXEG110X airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan QTXEG110X
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 85 sq ft1 CFM/sq ft @ 85.6 CFM
Tall Bath (9-ft Ceiling)Up to 76 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 35 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.5 kWh/yr (~$1.36/yr)23.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2205.0 kWh/yr (~$32.80/yr)23.4 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Broan QTXEG110X?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Nutone RN110 110 / 91 CFM 0.4 sones (Same) 3.7 CFM/W 4 in. diameter
Kaze Appliance SEP120 120 / 94.2 CFM 0.3 sones (-0.10) 4.2 CFM/W 6 in. diameter
S&P PC110XP 120 / 94.2 CFM 0.3 sones (-0.10) 4.2 CFM/W 6 in. diameter
Kaze Appliance SEP120 100 / 83.8 CFM 0.5 sones (+0.10) 3.6 CFM/W 4 in. diameter
Dayton 5AE70B 120 / N/A CFM 0.5 sones (+0.10) 6.2 CFM/W 6 x 8 in. rectangular

Does Broan QTXEG110X match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan QTXEG110X percentage capacity without sending data.

Who should not install Broan QTXEG110X in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan QTXEG110X for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 35 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 85.6 CFM net static output
  • Primary match: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Broan QTXEG110X?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan QTXEG110X.

Why check Broan QTXEG110X CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan QTXEG110X registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

How does Broan QTXEG110X sound output compare to noisy contractor-grade fans?

Rated at 0.4 sones, Broan QTXEG110X operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Broan QTXEG110X?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan QTXEG110X pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan QTXEG110X's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan QTXEG110X?

Broan QTXEG110X features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan QTXEG110X's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan QTXEG110X's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan QTXEG110X satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan QTXEG110X clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Broan QTXEG110X undersized or poorly matched for a bath renovation?

Skip Broan QTXEG110X if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories