ENERGY STAR PD #2248867 · Bathroom/Utility Room · Qualified 2015-10-01
Verified Specification Summary

Tested under HVI protocols, the Broan RB110 exhaust unit achieves 110 CFM at 0.1 in. w.g. (91 CFM at 0.25 in. w.g.), registers #50 of 607 in quietness (0.4 sones) and delivers 3.7 CFM/W efficacy, covering standard baths up to 91 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan RB110 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 91 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
3.7 CFM/W (#987/1,145)
Static Retention
82.7% @ 0.25"
Motor Draw
29.7 W (10.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan RB110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 91 CFM at 0.25 in. w.g. (82.7% retention, 5.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Broan's 207-unit lineup, RB110 (series: Ultra Pro) carries PD #2248867 dating to 2015-10-01. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 29.7 watts, about 10.8 kWh/yr (~$1.73/yr at $0.16/kWh) for 1 hr/day shower timers or 260.2 kWh/yr (~$41.63/yr) continuously. Closest competing matches include Nutone RN110 (110.0 CFM) and Kaze Appliance SEP120 (100.0 CFM).

Where do Broan RB110 sones rank across EPA ENERGY STAR fans?

Comparing Broan RB110 (0.4 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

What attic duct routing preserves Broan RB110 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan RB110, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan RB110 measure up on airflow and noise ratings?

Each row below breaks down Broan RB110 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series RB110 / Ultra Pro PD ID 2248867 (Qualified 2015-10-01)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (91 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Broan RB110 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan RB110
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 91 sq ft1 CFM/sq ft @ 91 CFM
Tall Bath (9-ft Ceiling)Up to 80 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 41 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.8 kWh/yr (~$1.73/yr)29.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2260.2 kWh/yr (~$41.63/yr)29.7 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan RB110?

Compare Broan RB110 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Nutone RN110 110 / 91 CFM 0.4 sones (Same) 3.7 CFM/W 4 in. diameter
Kaze Appliance SEP120 100 / 83.8 CFM 0.5 sones (+0.10) 3.6 CFM/W 4 in. diameter
Kaze Appliance SEP120 120 / 94.2 CFM 0.3 sones (-0.10) 4.2 CFM/W 6 in. diameter
S&P PC110XP 120 / 94.2 CFM 0.3 sones (-0.10) 4.2 CFM/W 6 in. diameter
AERO PURE ABF110L5W 110 / 89 CFM 0.7 sones (+0.30) 4.4 CFM/W 4 in. diameter

Can you size Broan RB110 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan RB110 verified capacity.

Who should not install Broan RB110 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan RB110 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 91 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 0.4 sones up to 91 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Broan RB110?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan RB110.

How does Broan RB110 sound output compare to noisy contractor-grade fans?

Rated at 0.4 sones, Broan RB110 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Broan RB110?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan RB110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan RB110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan RB110?

Broan RB110 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan RB110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan RB110's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan RB110 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan RB110 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Broan RB110 undersized or poorly matched for a bath renovation?

Skip Broan RB110 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Broan RB110 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan RB110 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories