Rated for 90 CFM open-air (80 CFM at 0.25 in. w.g.), Greenheck SP-A90 registers #50 of 607 in quietness (0.4 sones) and delivers 5.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 80 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A90 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 80 CFM
- Noise @ 0.1"
- 0.4 sones (#50/607)
- Efficacy Rank
- 5.5 CFM/W (#471/1,145)
- Static Retention
- 88.9% @ 0.25"
- Motor Draw
- 16.4 W (6.0 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Greenheck SP-A90 vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 80 CFM out of 90 CFM (88.9% retention, 1.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Greenheck's 31-unit lineup, SP-A90 (series: SP) carries PD #2335046 dating to 2015-10-15. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.4 watts, about 6.0 kWh/yr (~$0.96/yr at $0.16/kWh) for 1 hr/day shower timers or 143.7 kWh/yr (~$22.99/yr) continuously. Closest competing matches include Dayton 3DPE4B (90.0 CFM) and AERO PURE ABF80G15W (80.0 CFM).
How does Greenheck SP-A90 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Greenheck SP-A90 (0.4 sones).
How do flex elbows choke Greenheck SP-A90 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Greenheck SP-A90 moving full rated CFM.
Does Greenheck SP-A90 meet residential exhaust fan code specs?
Inspect Greenheck SP-A90 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Greenheck (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SP-A90 / SP | PD ID 2335046 (Qualified 2015-10-15) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (80 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.4 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Greenheck SP-A90 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Greenheck SP-A90 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 80 sq ft | 1 CFM/sq ft @ 80 CFM |
| Tall Bath (9-ft Ceiling) | Up to 71 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 30 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.0 kWh/yr (~$0.96/yr) | 16.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 143.7 kWh/yr (~$22.99/yr) | 16.4 W x 8,760 hrs / 1,000 |
Which competing models share Greenheck SP-A90 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Dayton 3DPE4B | 90 / N/A CFM | 0.4 sones (Same) | 5.5 CFM/W | 6 in. diameter |
| AERO PURE ABF80G15W | 80 / 62.9 CFM | 0.4 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| AERO PURE ABF80G16W | 80 / 62.9 CFM | 0.4 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| AUPU AV08A1 | 80 / 62.9 CFM | 0.4 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Broan QTXEG080 | 80 / 85.6 CFM | 0.4 sones (Same) | 4.7 CFM/W | 6 in. diameter |
How much airflow margin does Greenheck SP-A90 give your bath?
Run a quick local room-volume check for Greenheck SP-A90 by entering square footage and ceiling height to spot under-vented steam risks early.
Does Greenheck SP-A90 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Greenheck SP-A90 for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 30 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 80 sq ft with 8-ft ceilings (71 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Greenheck SP-A90?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Greenheck SP-A90.
How many kWh per year does Greenheck SP-A90 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Greenheck SP-A90 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Greenheck SP-A90 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A90's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Greenheck SP-A90?
Greenheck SP-A90 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Greenheck SP-A90's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A90's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Greenheck SP-A90 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-A90 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Greenheck SP-A90 in a bathroom remodel?
Avoid specifying Greenheck SP-A90 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Greenheck SP-A90 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Greenheck SP-A90 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Greenheck SP-A90 occupy in EPA filings?
With 0.4 sones at 0.1 in. w.g., Greenheck SP-A90 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)