Skip to main content
Grant Estimator

Greenheck SP-A90 Exhaust Fan Specifications

ENERGY STAR PD #2335046 · Bathroom/Utility Room · Qualified 2015-10-15
Verified Specification Summary

Rated for 90 CFM open-air (80 CFM at 0.25 in. w.g.), Greenheck SP-A90 registers #50 of 607 in quietness (0.4 sones) and delivers 5.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 80 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A90 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 80 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
5.5 CFM/W (#471/1,145)
Static Retention
88.9% @ 0.25"
Motor Draw
16.4 W (6.0 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck SP-A90 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 80 CFM out of 90 CFM (88.9% retention, 1.2 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Greenheck's 31-unit lineup, SP-A90 (series: SP) carries PD #2335046 dating to 2015-10-15. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.4 watts, about 6.0 kWh/yr (~$0.96/yr at $0.16/kWh) for 1 hr/day shower timers or 143.7 kWh/yr (~$22.99/yr) continuously. Closest competing matches include Dayton 3DPE4B (90.0 CFM) and AERO PURE ABF80G15W (80.0 CFM).

How does Greenheck SP-A90 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Greenheck SP-A90 (0.4 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

How do flex elbows choke Greenheck SP-A90 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Greenheck SP-A90 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Greenheck SP-A90 meet residential exhaust fan code specs?

Inspect Greenheck SP-A90 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series SP-A90 / SP PD ID 2335046 (Qualified 2015-10-15)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (80 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Greenheck SP-A90 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Greenheck SP-A90 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Greenheck SP-A90
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 80 sq ft1 CFM/sq ft @ 80 CFM
Tall Bath (9-ft Ceiling)Up to 71 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 30 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.0 kWh/yr (~$0.96/yr)16.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2143.7 kWh/yr (~$22.99/yr)16.4 W x 8,760 hrs / 1,000

Which competing models share Greenheck SP-A90 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 3DPE4B 90 / N/A CFM 0.4 sones (Same) 5.5 CFM/W 6 in. diameter
AERO PURE ABF80G15W 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
AERO PURE ABF80G16W 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
AUPU AV08A1 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
Broan QTXEG080 80 / 85.6 CFM 0.4 sones (Same) 4.7 CFM/W 6 in. diameter

How much airflow margin does Greenheck SP-A90 give your bath?

Run a quick local room-volume check for Greenheck SP-A90 by entering square footage and ceiling height to spot under-vented steam risks early.

Does Greenheck SP-A90 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Greenheck SP-A90 for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 30 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 80 sq ft with 8-ft ceilings (71 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about Greenheck SP-A90?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Greenheck SP-A90.

How many kWh per year does Greenheck SP-A90 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Greenheck SP-A90 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Greenheck SP-A90 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A90's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck SP-A90?

Greenheck SP-A90 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck SP-A90's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A90's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Greenheck SP-A90 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-A90 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Greenheck SP-A90 in a bathroom remodel?

Avoid specifying Greenheck SP-A90 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Greenheck SP-A90 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Greenheck SP-A90 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Greenheck SP-A90 occupy in EPA filings?

With 0.4 sones at 0.1 in. w.g., Greenheck SP-A90 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories