AUPU AV08A1 Exhaust Fan Specifications

ENERGY STAR PD #2856278 · Bathroom/Utility Room · Qualified 2023-12-15
Verified Specification Summary

Certified by EPA ENERGY STAR, AUPU AV08A1 delivers 80 CFM free-air (62.9 CFM at 0.25 in. w.g.) and registers #50 of 607 in quietness (0.4 sones) and delivers 4.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 62 sq ft (8-ft height) or 55 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU AV08A1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 62.9 CFM
Noise @ 0.1"
0.4 sones (#50/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
78.6% @ 0.25"
Motor Draw
17.0 W (6.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AUPU AV08A1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.4 sones (#50 of 607 rated models, quietest 13.5% of 607 rated models, quieter than 86.5% of rated models, 0.60 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.9 CFM at 0.25 in. w.g. (78.6% retention, 9.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2856278 verifies AV08A1 (series: AV) under AUPU (35 listed models, qualified 2023-12-15). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include AERO PURE ABF80G15W (80.0 CFM) and AERO PURE ABF80G16W (80.0 CFM).

How noisy is AUPU AV08A1 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while AUPU AV08A1 measures 0.4 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.4 sone: 0.4 sones (14th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.4 sone: 0.4 sones (P14)

Why does rigid 4 in. diameter ducting protect AUPU AV08A1 airflow?

Connecting AUPU AV08A1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify AUPU AV08A1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for AUPU AV08A1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AUPU (35 models) ENERGY STAR Certified Partner
Model Number & Series AV08A1 / AV PD ID 2856278 (Qualified 2023-12-15)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (62.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.4 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit AUPU AV08A1?

Calculated coverage metrics translate AUPU AV08A1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for AUPU AV08A1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 62 sq ft1 CFM/sq ft @ 62.9 CFM
Tall Bath (9-ft Ceiling)Up to 55 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.2 kWh/yr (~$0.99/yr)17.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2148.9 kWh/yr (~$23.82/yr)17.0 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to AUPU AV08A1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
AERO PURE ABF80G15W 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
AERO PURE ABF80G16W 80 / 62.9 CFM 0.4 sones (Same) 4.7 CFM/W 4 in. diameter
Broan QTXEG080 80 / 85.6 CFM 0.4 sones (Same) 4.7 CFM/W 6 in. diameter
Broan QTXEG080 = QTXEGH with QTXEG080F 80 / 85.6 CFM 0.4 sones (Same) 4.7 CFM/W 6 in. diameter
Broan QTXEG080X 80 / 85.6 CFM 0.4 sones (Same) 4.7 CFM/W 6 in. diameter

Does AUPU AV08A1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AUPU AV08A1 percentage capacity without sending data.

Who should not install AUPU AV08A1 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting AUPU AV08A1 for residential use.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 62.9 CFM net static output
  • Primary match: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for AUPU AV08A1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AUPU AV08A1.

When is AUPU AV08A1 undersized or poorly matched for a bath renovation?

Skip AUPU AV08A1 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check AUPU AV08A1 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, AUPU AV08A1 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does AUPU AV08A1 sound output compare to noisy contractor-grade fans?

Rated at 0.4 sones, AUPU AV08A1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define AUPU AV08A1?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can AUPU AV08A1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU AV08A1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AUPU AV08A1?

AUPU AV08A1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AUPU AV08A1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU AV08A1's safe coverage footprint from 50 sq ft to 44 sq ft.

Does AUPU AV08A1 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), AUPU AV08A1 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.