In EPA dataset 8dv7-nngq, S&P PC150XP tests at 150 CFM free discharge (123.8 CFM at 0.25 in. w.g.) and registers #83 of 607 in quietness (0.5 sones) and delivers 4.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 123 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PC150XP Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 123.8 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 4.6 CFM/W (#578/1,145)
- Static Retention
- 82.5% @ 0.25"
- Motor Draw
- 32.6 W (11.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does S&P PC150XP vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 123.8 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Manufacturer coverage places PC150XP (series: PC) (PD #2402468) among 29 S&P entries qualified through 2022-09-16. Lighting kit: No. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include ACIQ AEP150 (150.0 CFM) and Anzzi EF-AZ104WH (150.0 CFM).
Does S&P PC150XP fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with S&P PC150XP at 0.5 sones.
Why avoid unvented attic termination with S&P PC150XP?
Under ASHRAE 62.2 best practice, S&P PC150XP needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern S&P PC150XP?
Before cutting ceiling drywall or sizing attic transitions for S&P PC150XP, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PC150XP / PC | PD ID 2402468 (Qualified 2022-09-16) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (123.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit S&P PC150XP?
Bathroom ventilation sizing below maps S&P PC150XP motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 123 sq ft | 1 CFM/sq ft @ 123.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 73 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |
What peer models sit nearest S&P PC150XP in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to S&P PC150XP.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AEP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Anzzi EF-AZ104WH | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Anzzi EF-AZ105WH | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Cyclone ESCBP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Kaze Appliance SEP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
What percentage of room demand does S&P PC150XP cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against S&P PC150XP tested delivery.
Where should contractors skip S&P PC150XP on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for S&P PC150XP carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 123.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around 0.5 sones up to 123 sq ft
- Works well for: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for S&P PC150XP?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing S&P PC150XP.
How loud is S&P PC150XP compared with a standard 3.0 sone builder fan?
Tested at 0.5 sones, S&P PC150XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does S&P PC150XP consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, S&P PC150XP draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can S&P PC150XP pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PC150XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P PC150XP?
S&P PC150XP features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P PC150XP's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PC150XP's safe coverage footprint from 50 sq ft to 44 sq ft.
How does S&P PC150XP score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), S&P PC150XP delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify S&P PC150XP?
Rule out S&P PC150XP when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke S&P PC150XP capacity?
Because static drag at 0.25 in. w.g. lowers S&P PC150XP from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)