Tested under HVI protocols, the Anzzi EF-AZ104WH exhaust unit achieves 150 CFM at 0.1 in. w.g. (123.8 CFM at 0.25 in. w.g.), registers #83 of 607 in quietness (0.5 sones) and delivers 4.6 CFM/W efficacy, covering standard baths up to 123 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Anzzi EF-AZ104WH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 123.8 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 4.6 CFM/W (#578/1,145)
- Static Retention
- 82.5% @ 0.25"
- Motor Draw
- 32.6 W (11.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Anzzi EF-AZ104WH vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 123.8 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #3425442 verifies EF-AZ104WH (series: EF) under Anzzi (8 listed models, qualified 2024-03-15). Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include ACIQ AEP150 (150.0 CFM) and Cyclone ESCBP150 (150.0 CFM).
Where do Anzzi EF-AZ104WH sones rank across EPA ENERGY STAR fans?
Comparing Anzzi EF-AZ104WH (0.5 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Anzzi EF-AZ104WH CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Anzzi EF-AZ104WH, preventing premature peeling paint and mold growth.
How does Anzzi EF-AZ104WH measure up on airflow and noise ratings?
Each row below breaks down Anzzi EF-AZ104WH certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Anzzi (8 models) | ENERGY STAR Certified Partner |
| Model Number & Series | EF-AZ104WH / EF | PD ID 3425442 (Qualified 2024-03-15) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (123.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Anzzi EF-AZ104WH CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 123 sq ft | 1 CFM/sq ft @ 123.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 73 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Anzzi EF-AZ104WH?
Compare Anzzi EF-AZ104WH side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AEP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Cyclone ESCBP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Kaze Appliance SEP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Ortech OD-1505PB | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| S&P PC150XP | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
Can you size Anzzi EF-AZ104WH for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Anzzi EF-AZ104WH verified capacity.
Who should not install Anzzi EF-AZ104WH in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Anzzi EF-AZ104WH for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 123.8 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 0.5 sones up to 123 sq ft
- Primary match: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Anzzi EF-AZ104WH?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Anzzi EF-AZ104WH.
When is Anzzi EF-AZ104WH undersized or poorly matched for a bath renovation?
Skip Anzzi EF-AZ104WH if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Anzzi EF-AZ104WH CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Anzzi EF-AZ104WH registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
How does Anzzi EF-AZ104WH sound output compare to noisy contractor-grade fans?
Rated at 0.5 sones, Anzzi EF-AZ104WH operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Anzzi EF-AZ104WH?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Anzzi EF-AZ104WH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Anzzi EF-AZ104WH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Anzzi EF-AZ104WH?
Anzzi EF-AZ104WH features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Anzzi EF-AZ104WH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Anzzi EF-AZ104WH's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Anzzi EF-AZ104WH satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Anzzi EF-AZ104WH clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.