Homeowners specifying Ortech OD-1505PB gain 150 CFM at 0.1 in. w.g. (123.8 CFM at 0.25 in. w.g.) where it registers #83 of 607 in quietness (0.5 sones) and delivers 4.6 CFM/W efficacy, venting bathrooms up to 123 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OD-1505PB Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 123.8 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 4.6 CFM/W (#578/1,145)
- Static Retention
- 82.5% @ 0.25"
- Motor Draw
- 32.6 W (11.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Ortech OD-1505PB vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 123.8 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Ortech registers 27 certified models, with SKU OD-1505PB (series: OD) (PD #2402466) certified since 2022-10-07. Lighting kit: No. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include ACIQ AEP150 (150.0 CFM) and Anzzi EF-AZ104WH (150.0 CFM).
What acoustic percentile does Ortech OD-1505PB occupy among 1,145 bath blowers?
Inspect how Ortech OD-1505PB positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Ortech OD-1505PB best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Ortech OD-1505PB housings.
Where do Ortech OD-1505PB acoustic and static metrics stand?
Compare Ortech OD-1505PB published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | OD-1505PB / OD | PD ID 2402466 (Qualified 2022-10-07) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (123.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Ortech OD-1505PB handle taller ceilings or walk-in tub steam?
Evaluate how Ortech OD-1505PB scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 123 sq ft | 1 CFM/sq ft @ 123.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 73 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Ortech OD-1505PB?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AEP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Anzzi EF-AZ104WH | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Anzzi EF-AZ105WH | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Cyclone ESCBP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Kaze Appliance SEP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
Is Ortech OD-1505PB sized right for your shower or tub room?
Check whether Ortech OD-1505PB clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Where should contractors skip Ortech OD-1505PB on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Ortech OD-1505PB carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 73 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 123.8 CFM net static output
- Works well for: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for Ortech OD-1505PB?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Ortech OD-1505PB.
How loud is Ortech OD-1505PB compared with a standard 3.0 sone builder fan?
Tested at 0.5 sones, Ortech OD-1505PB operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Ortech OD-1505PB consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Ortech OD-1505PB draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Ortech OD-1505PB pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OD-1505PB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech OD-1505PB?
Ortech OD-1505PB features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech OD-1505PB's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OD-1505PB's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Ortech OD-1505PB score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Ortech OD-1505PB delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Ortech OD-1505PB?
Rule out Ortech OD-1505PB when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Ortech OD-1505PB capacity?
Because static drag at 0.25 in. w.g. lowers Ortech OD-1505PB from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)