Certified by EPA ENERGY STAR, Anzzi EF-AZ105WH delivers 150 CFM free-air (123.8 CFM at 0.25 in. w.g.) and registers #83 of 607 in quietness (0.5 sones) and delivers 4.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 123 sq ft (8-ft height) or 110 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Anzzi EF-AZ105WH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 123.8 CFM
- Noise @ 0.1"
- 0.5 sones (#83/607)
- Efficacy Rank
- 4.6 CFM/W (#578/1,145)
- Static Retention
- 82.5% @ 0.25"
- Motor Draw
- 32.6 W (11.9 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Anzzi EF-AZ105WH vs. 1,145-Model ENERGY STAR Benchmarks show?
Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 123.8 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Anzzi maintains 8 active ENERGY STAR blowers; EF-AZ105WH (series: EF) (PD #3425443) gained qualification on 2024-03-15. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include ACIQ AEP150 (150.0 CFM) and Cyclone ESCBP150 (150.0 CFM).
How noisy is Anzzi EF-AZ105WH compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Anzzi EF-AZ105WH measures 0.5 sones across the 1,145-model registry.
Why does rigid 6 in. diameter ducting protect Anzzi EF-AZ105WH airflow?
Connecting Anzzi EF-AZ105WH through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Anzzi EF-AZ105WH performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Anzzi EF-AZ105WH lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Anzzi (8 models) | ENERGY STAR Certified Partner |
| Model Number & Series | EF-AZ105WH / EF | PD ID 3425443 (Qualified 2024-03-15) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (123.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.5 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Anzzi EF-AZ105WH?
Calculated coverage metrics translate Anzzi EF-AZ105WH airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 123 sq ft | 1 CFM/sq ft @ 123.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 73 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Anzzi EF-AZ105WH?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AEP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Cyclone ESCBP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Kaze Appliance SEP150 | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| Ortech OD-1505PB | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
| S&P PC150XP | 150 / 123.8 CFM | 0.5 sones (Same) | 4.6 CFM/W | 6 in. diameter |
Does Anzzi EF-AZ105WH match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Anzzi EF-AZ105WH percentage capacity without sending data.
What plumbing or duct constraints rule out Anzzi EF-AZ105WH?
Compare where Anzzi EF-AZ105WH excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 73 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 123.8 CFM net static output
- Suited to: Collar pairs with 6 in. diameter duct straight outdoors
Which homeowner questions come up most for Anzzi EF-AZ105WH?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Anzzi EF-AZ105WH.
Is Anzzi EF-AZ105WH quiet enough for a primary bedroom bathroom?
At 0.5 sones, Anzzi EF-AZ105WH operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Anzzi EF-AZ105WH energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Anzzi EF-AZ105WH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Anzzi EF-AZ105WH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Anzzi EF-AZ105WH?
Anzzi EF-AZ105WH features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Anzzi EF-AZ105WH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Anzzi EF-AZ105WH's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Anzzi EF-AZ105WH serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Anzzi EF-AZ105WH supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Anzzi EF-AZ105WH for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Anzzi EF-AZ105WH lacks adequate reserve.
How does Anzzi EF-AZ105WH handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Anzzi EF-AZ105WH yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.