Skip to main content
Grant Estimator

Cyclone ESCBP150 Exhaust Fan Specifications

ENERGY STAR PD #2409638 · Bathroom/Utility Room · Qualified 2023-02-24
Verified Specification Summary

Certified by EPA ENERGY STAR, Cyclone ESCBP150 delivers 150 CFM free-air (123.8 CFM at 0.25 in. w.g.) and registers #83 of 607 in quietness (0.5 sones) and delivers 4.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 123 sq ft (8-ft height) or 110 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone ESCBP150 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 123.8 CFM
Noise @ 0.1"
0.5 sones (#83/607)
Efficacy Rank
4.6 CFM/W (#578/1,145)
Static Retention
82.5% @ 0.25"
Motor Draw
32.6 W (11.9 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Cyclone ESCBP150 vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.5 sones (#83 of 607 rated models, quietest 17.5% of 607 rated models, quieter than 82.5% of rated models, 0.50 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 123.8 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: Cyclone registers 17 certified models, with SKU ESCBP150 (series: ESCBP) (PD #2409638) certified since 2023-02-24. Lighting kit: No. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include ACIQ AEP150 (150.0 CFM) and Anzzi EF-AZ104WH (150.0 CFM).

How noisy is Cyclone ESCBP150 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Cyclone ESCBP150 measures 0.5 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.5 sone: 0.5 sones (17th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.5 sone: 0.5 sones (P17)

Why does rigid 6 in. diameter ducting protect Cyclone ESCBP150 airflow?

Connecting Cyclone ESCBP150 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Cyclone ESCBP150 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Cyclone ESCBP150 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Cyclone (17 models) ENERGY STAR Certified Partner
Model Number & Series ESCBP150 / ESCBP PD ID 2409638 (Qualified 2023-02-24)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (123.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.5 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Cyclone ESCBP150?

Calculated coverage metrics translate Cyclone ESCBP150 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Cyclone ESCBP150
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 123 sq ft1 CFM/sq ft @ 123.8 CFM
Tall Bath (9-ft Ceiling)Up to 110 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 73 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.9 kWh/yr (~$1.90/yr)32.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2285.6 kWh/yr (~$45.70/yr)32.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Cyclone ESCBP150?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ AEP150 150 / 123.8 CFM 0.5 sones (Same) 4.6 CFM/W 6 in. diameter
Anzzi EF-AZ104WH 150 / 123.8 CFM 0.5 sones (Same) 4.6 CFM/W 6 in. diameter
Anzzi EF-AZ105WH 150 / 123.8 CFM 0.5 sones (Same) 4.6 CFM/W 6 in. diameter
Kaze Appliance SEP150 150 / 123.8 CFM 0.5 sones (Same) 4.6 CFM/W 6 in. diameter
Ortech OD-1505PB 150 / 123.8 CFM 0.5 sones (Same) 4.6 CFM/W 6 in. diameter

Does Cyclone ESCBP150 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Cyclone ESCBP150 percentage capacity without sending data.

Which bath layouts should avoid specifying Cyclone ESCBP150?

Match Cyclone ESCBP150 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 73 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 123.8 CFM net static output
  • Optimal use: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Cyclone ESCBP150?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Cyclone ESCBP150.

Where does Cyclone ESCBP150 sit on acoustic comfort for senior homeowners?

Measuring 0.5 sones, Cyclone ESCBP150 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Cyclone ESCBP150 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Cyclone ESCBP150 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Cyclone ESCBP150 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone ESCBP150's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Cyclone ESCBP150?

Cyclone ESCBP150 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Cyclone ESCBP150's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone ESCBP150's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Cyclone ESCBP150 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Cyclone ESCBP150 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Cyclone ESCBP150 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Cyclone ESCBP150.

What happens to Cyclone ESCBP150 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Cyclone ESCBP150 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories