Homeowners specifying KORA SBF90DC-MS gain 98.1 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it registers #135 of 607 in quietness (0.7 sones) and delivers 10.7 CFM/W efficacy, venting bathrooms up to 98 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KORA SBF90DC-MS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
98.1 / N/A CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
10.7 CFM/W (#144/1,145)
Static Retention
0.1" test only
Motor Draw
9.2 W (3.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does KORA SBF90DC-MS vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Free-discharge delivery reaches 98.1 CFM (#784 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2399644 verifies SBF90DC-MS (series: FAN) under KORA (5 listed models, qualified 2022-07-19). Lighting kit: No. At 10.7 CFM/W (#144 of 1,145, top 13.2% of 1,145 rated models, more efficient than 86.8% of rated models, 6.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.2 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 80.6 kWh/yr (~$12.90/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-E110THA (110.0 CFM) and Revent RVS110 (110.0 CFM).

What acoustic percentile does KORA SBF90DC-MS occupy among 1,145 bath blowers?

Inspect how KORA SBF90DC-MS positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

Which exterior damper path suits KORA SBF90DC-MS best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around KORA SBF90DC-MS housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do KORA SBF90DC-MS acoustic and static metrics stand?

Compare KORA SBF90DC-MS published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share KORA (5 models) ENERGY STAR Certified Partner
Model Number & Series SBF90DC-MS / FAN PD ID 2399644 (Qualified 2022-07-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (98.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can KORA SBF90DC-MS handle taller ceilings or walk-in tub steam?

Evaluate how KORA SBF90DC-MS scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for KORA SBF90DC-MS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 98 sq ft1 CFM/sq ft @ 98.1 CFM
Tall Bath (9-ft Ceiling)Up to 87 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 48 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.4 kWh/yr (~$0.54/yr)9.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.280.6 kWh/yr (~$12.90/yr)9.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near KORA SBF90DC-MS?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-E110THA 110 / 110.3 CFM 0.5 sones (-0.20) 9.9 CFM/W 4 in. diameter
Revent RVS110 110 / 119.2 CFM 0.8 sones (+0.10) 12.3 CFM/W 4 in. diameter
Revent RVSH110 110 / 119.2 CFM 0.8 sones (+0.10) 12.3 CFM/W 4 in. diameter
Ortech ODD-90-1 95 / 78.9 CFM 0.7 sones (Same) 13.2 CFM/W 4 in. diameter
Delta 80F 80 / 68.8 CFM 0.8 sones (+0.10) 9.5 CFM/W 4 in. diameter

Is KORA SBF90DC-MS sized right for your shower or tub room?

Check whether KORA SBF90DC-MS clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Which bath layouts should avoid specifying KORA SBF90DC-MS?

Match KORA SBF90DC-MS directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 48 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 98.1 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for KORA SBF90DC-MS?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to KORA SBF90DC-MS.

What does KORA SBF90DC-MS cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running KORA SBF90DC-MS 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can KORA SBF90DC-MS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KORA SBF90DC-MS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing KORA SBF90DC-MS?

KORA SBF90DC-MS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change KORA SBF90DC-MS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KORA SBF90DC-MS's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can KORA SBF90DC-MS ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), KORA SBF90DC-MS covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does KORA SBF90DC-MS run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with KORA SBF90DC-MS.

What happens to KORA SBF90DC-MS CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, KORA SBF90DC-MS moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does KORA SBF90DC-MS sit on acoustic comfort for senior homeowners?

Measuring 0.7 sones, KORA SBF90DC-MS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories