Certified by EPA ENERGY STAR, Greenheck SP-A125 delivers 109 CFM free-air (unpublished 0.25 in. w.g. output) and registers #135 of 607 in quietness (0.7 sones) and delivers 5.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 109 sq ft (8-ft height) or 96 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-A125 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 109 / N/A CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 5.8 CFM/W (#461/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 18.8 W (6.9 kWh/yr)
- Duct & Tier
- 6 x 8 in. rectangular · Standard

What does Greenheck SP-A125 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Free-discharge delivery reaches 109 CFM (#620 of 1,145 certified models) via a 6 x 8 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.
Greenheck maintains 31 active ENERGY STAR blowers; SP-A125 (series: SP) (PD #2335073) gained qualification on 2015-10-15. Lighting kit: No. At 5.8 CFM/W (#461 of 1,145, top 40.7% of 1,145 rated models, more efficient than 59.3% of rated models, 1.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.8 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 164.7 kWh/yr (~$26.35/yr) continuously. Closest competing matches include AERO PURE ABF110L5W (110.0 CFM) and AUPU AV11AL1 (110.0 CFM).
How noisy is Greenheck SP-A125 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Greenheck SP-A125 measures 0.7 sones across the 1,145-model registry.
Why does rigid 6 x 8 in. rectangular ducting protect Greenheck SP-A125 airflow?
Connecting Greenheck SP-A125 through rigid 6 x 8 in. rectangular steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Greenheck SP-A125 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Greenheck SP-A125 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Greenheck (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SP-A125 / SP | PD ID 2335073 (Qualified 2015-10-15) |
| Duct Connection | 6 x 8 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (109 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Greenheck SP-A125?
Calculated coverage metrics translate Greenheck SP-A125 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 109 sq ft | 1 CFM/sq ft @ 109 CFM |
| Tall Bath (9-ft Ceiling) | Up to 96 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 59 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.9 kWh/yr (~$1.10/yr) | 18.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 164.7 kWh/yr (~$26.35/yr) | 18.8 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Greenheck SP-A125?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| AERO PURE ABF110L5W | 110 / 89 CFM | 0.7 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AUPU AV11AL1 | 110 / 89 CFM | 0.7 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AUPU AV11AL2 | 110 / 89 CFM | 0.7 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| ACIQ ANP100 | 100 / 97.3 CFM | 0.8 sones (+0.10) | 4.7 CFM/W | 4 in. diameter |
| Canarm CNP100 | 100 / 97.3 CFM | 0.8 sones (+0.10) | 4.7 CFM/W | 4 in. diameter |
Does Greenheck SP-A125 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Greenheck SP-A125 percentage capacity without sending data.
Where should contractors skip Greenheck SP-A125 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Greenheck SP-A125 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 59 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 109 CFM net static output
- Works well for: Collar pairs with 6 x 8 in. rectangular duct straight outdoors
Which homeowner questions come up most for Greenheck SP-A125?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Greenheck SP-A125.
What duct and room conditions disqualify Greenheck SP-A125?
Rule out Greenheck SP-A125 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Greenheck SP-A125 capacity?
Because static drag at 0.25 in. w.g. lowers Greenheck SP-A125 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 x 8 in. rectangular rigid ducting straight to a dedicated exterior damper.
How loud is Greenheck SP-A125 compared with a standard 3.0 sone builder fan?
Tested at 0.7 sones, Greenheck SP-A125 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Greenheck SP-A125 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Greenheck SP-A125 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Greenheck SP-A125 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-A125's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Greenheck SP-A125?
Greenheck SP-A125 features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Greenheck SP-A125's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-A125's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Greenheck SP-A125 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Greenheck SP-A125 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)