Skip to main content
Grant Estimator

ACIQ ANP100 Exhaust Fan Specifications

ENERGY STAR PD #3629719 · Bathroom/Utility Room · Qualified 2024-09-27
Verified Specification Summary

In EPA dataset 8dv7-nngq, ACIQ ANP100 tests at 100 CFM free discharge (97.3 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 4.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 97 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ ANP100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 97.3 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
97.3% @ 0.25"
Motor Draw
21.3 W (7.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does ACIQ ANP100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.3 CFM out of 100 CFM (97.3% retention, 9.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3629719 verifies ANP100 (series: ANP) under ACIQ (15 listed models, qualified 2024-09-27). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 21.3 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 186.6 kWh/yr (~$29.86/yr) continuously. Closest competing matches include Canarm CNP100 (100.0 CFM) and Cyclone CBP100 (100.0 CFM).

Does ACIQ ANP100 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with ACIQ ANP100 at 0.8 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

Why avoid unvented attic termination with ACIQ ANP100?

Under ASHRAE 62.2 best practice, ACIQ ANP100 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern ACIQ ANP100?

Before cutting ceiling drywall or sizing attic transitions for ACIQ ANP100, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share ACIQ (15 models) ENERGY STAR Certified Partner
Model Number & Series ANP100 / ANP PD ID 3629719 (Qualified 2024-09-27)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (97.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit ACIQ ANP100?

Bathroom ventilation sizing below maps ACIQ ANP100 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for ACIQ ANP100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 97 sq ft1 CFM/sq ft @ 97.3 CFM
Tall Bath (9-ft Ceiling)Up to 86 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 47 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.8 kWh/yr (~$1.25/yr)21.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2186.6 kWh/yr (~$29.86/yr)21.3 W x 8,760 hrs / 1,000

What peer models sit nearest ACIQ ANP100 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to ACIQ ANP100.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Canarm CNP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Cyclone CBP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Cyclone CTP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Kaze Appliance SNP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
QuFresh BC100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter

What percentage of room demand does ACIQ ANP100 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against ACIQ ANP100 tested delivery.

Does ACIQ ANP100 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying ACIQ ANP100 for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 97.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 0.8 sones up to 97 sq ft
  • Best application: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for ACIQ ANP100?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing ACIQ ANP100.

What acoustic sone tier does ACIQ ANP100 occupy in EPA filings?

With 0.8 sones at 0.1 in. w.g., ACIQ ANP100 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does ACIQ ANP100 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, ACIQ ANP100 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can ACIQ ANP100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ ANP100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing ACIQ ANP100?

ACIQ ANP100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change ACIQ ANP100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ ANP100's safe coverage footprint from 50 sq ft to 44 sq ft.

Does ACIQ ANP100 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), ACIQ ANP100 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install ACIQ ANP100 in a bathroom remodel?

Avoid specifying ACIQ ANP100 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut ACIQ ANP100 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, ACIQ ANP100 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories