Skip to main content
Grant Estimator

Cyclone CTP100 Exhaust Fan Specifications

ENERGY STAR PD #2409644 · Bathroom/Utility Room · Qualified 2023-02-03
Verified Specification Summary

Rated for 100 CFM open-air (97.3 CFM at 0.25 in. w.g.), Cyclone CTP100 registers #194 of 607 in quietness (0.8 sones) and delivers 4.7 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 97 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone CTP100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 97.3 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
97.3% @ 0.25"
Motor Draw
21.3 W (7.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Cyclone CTP100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.3 CFM out of 100 CFM (97.3% retention, 9.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Cyclone's 17-unit lineup, CTP100 (series: CTP) carries PD #2409644 dating to 2023-02-03. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 21.3 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 186.6 kWh/yr (~$29.86/yr) continuously. Closest competing matches include ACIQ ANP100 (100.0 CFM) and Canarm CNP100 (100.0 CFM).

How does Cyclone CTP100 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Cyclone CTP100 (0.8 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

How do flex elbows choke Cyclone CTP100 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Cyclone CTP100 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Cyclone CTP100 meet residential exhaust fan code specs?

Inspect Cyclone CTP100 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Cyclone (17 models) ENERGY STAR Certified Partner
Model Number & Series CTP100 / CTP PD ID 2409644 (Qualified 2023-02-03)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (97.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Cyclone CTP100 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Cyclone CTP100 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Cyclone CTP100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 97 sq ft1 CFM/sq ft @ 97.3 CFM
Tall Bath (9-ft Ceiling)Up to 86 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 47 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.8 kWh/yr (~$1.25/yr)21.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2186.6 kWh/yr (~$29.86/yr)21.3 W x 8,760 hrs / 1,000

Which competing models share Cyclone CTP100 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ ANP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Canarm CNP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Kaze Appliance SNP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
QuFresh BC100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
AUPU B4-10F 100 / 81.9 CFM 0.8 sones (Same) 4.0 CFM/W 4 in. diameter

How much airflow margin does Cyclone CTP100 give your bath?

Run a quick local room-volume check for Cyclone CTP100 by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Cyclone CTP100 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Cyclone CTP100 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 47 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 97 sq ft with 8-ft ceilings (86 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Cyclone CTP100?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Cyclone CTP100.

How does Cyclone CTP100 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Cyclone CTP100 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Cyclone CTP100?

Rule out Cyclone CTP100 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Cyclone CTP100 capacity?

Because static drag at 0.25 in. w.g. lowers Cyclone CTP100 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Cyclone CTP100 compared with a standard 3.0 sone builder fan?

Tested at 0.8 sones, Cyclone CTP100 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Cyclone CTP100 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Cyclone CTP100 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Cyclone CTP100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone CTP100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Cyclone CTP100?

Cyclone CTP100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Cyclone CTP100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone CTP100's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories