Canarm CNP100 Exhaust Fan Specifications

ENERGY STAR PD #4510683 · Bathroom/Utility Room · Qualified 2025-08-22
Verified Specification Summary

Rated for 100 CFM open-air (97.3 CFM at 0.25 in. w.g.), Canarm CNP100 registers #194 of 607 in quietness (0.8 sones) and delivers 4.7 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 97 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Canarm CNP100 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 97.3 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
97.3% @ 0.25"
Motor Draw
21.3 W (7.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Canarm CNP100 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.3 CFM out of 100 CFM (97.3% retention, 9.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4510683 verifies CNP100 (series: CNP) under Canarm (5 listed models, qualified 2025-08-22). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 21.3 watts, about 7.8 kWh/yr (~$1.25/yr at $0.16/kWh) for 1 hr/day shower timers or 186.6 kWh/yr (~$29.86/yr) continuously. Closest competing matches include ACIQ ANP100 (100.0 CFM) and Cyclone CBP100 (100.0 CFM).

How does Canarm CNP100 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Canarm CNP100 (0.8 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

How do flex elbows choke Canarm CNP100 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Canarm CNP100 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Canarm CNP100 meet residential exhaust fan code specs?

Inspect Canarm CNP100 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Canarm (5 models) ENERGY STAR Certified Partner
Model Number & Series CNP100 / CNP PD ID 4510683 (Qualified 2025-08-22)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (97.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Canarm CNP100 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Canarm CNP100 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Canarm CNP100
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 97 sq ft1 CFM/sq ft @ 97.3 CFM
Tall Bath (9-ft Ceiling)Up to 86 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 47 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.8 kWh/yr (~$1.25/yr)21.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2186.6 kWh/yr (~$29.86/yr)21.3 W x 8,760 hrs / 1,000

Which competing models share Canarm CNP100 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ ANP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Cyclone CBP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Cyclone CTP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
Kaze Appliance SNP100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter
QuFresh BC100 100 / 97.3 CFM 0.8 sones (Same) 4.7 CFM/W 4 in. diameter

How much airflow margin does Canarm CNP100 give your bath?

Run a quick local room-volume check for Canarm CNP100 by entering square footage and ceiling height to spot under-vented steam risks early.

Which bath layouts should avoid specifying Canarm CNP100?

Match Canarm CNP100 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 47 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 97 sq ft with 8-ft ceilings (86 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Canarm CNP100?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Canarm CNP100.

Where does Canarm CNP100 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Canarm CNP100.

What happens to Canarm CNP100 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Canarm CNP100 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Canarm CNP100 sit on acoustic comfort for senior homeowners?

Measuring 0.8 sones, Canarm CNP100 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Canarm CNP100 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Canarm CNP100 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Canarm CNP100 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Canarm CNP100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Canarm CNP100?

Canarm CNP100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Canarm CNP100's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Canarm CNP100's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Canarm CNP100 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Canarm CNP100 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)