Certified by EPA ENERGY STAR, AUPU BF4-10L delivers 100 CFM free-air (79.8 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 3.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 79 sq ft (8-ft height) or 70 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU BF4-10L Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 79.8 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 79.8% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU BF4-10L vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 100 CFM open-air to 79.8 CFM at 0.25 in. w.g. (79.8% retention, 7.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: AUPU registers 35 certified models, with SKU BF4-10L (series: BF4) (PD #4619014) certified since 2026-05-27. Lighting kit: Yes. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include VOTATEC VO-FN4W26-AC-100 (100.0 CFM) and Wintek BPT15B-100H1 (100.0 CFM).
How noisy is AUPU BF4-10L compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while AUPU BF4-10L measures 0.8 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect AUPU BF4-10L airflow?
Connecting AUPU BF4-10L through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify AUPU BF4-10L performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for AUPU BF4-10L lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BF4-10L / BF4 | PD ID 4619014 (Qualified 2026-05-27) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (79.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit AUPU BF4-10L?
Calculated coverage metrics translate AUPU BF4-10L airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 79 sq ft | 1 CFM/sq ft @ 79.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 29 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to AUPU BF4-10L?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| VOTATEC VO-FN4W26-AC-100 | 100 / 85 CFM | 0.9 sones (+0.10) | 3.9 CFM/W | 4 in. diameter |
| Wintek BPT15B-100H1 | 100 / 85 CFM | 0.9 sones (+0.10) | 3.9 CFM/W | 4 in. diameter |
| ACIQ ANP100 | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Canarm CNP100 | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Cyclone CBP100 | 100 / 97.3 CFM | 0.8 sones (Same) | 4.7 CFM/W | 4 in. diameter |
Does AUPU BF4-10L match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AUPU BF4-10L percentage capacity without sending data.
What plumbing or duct constraints rule out AUPU BF4-10L?
Compare where AUPU BF4-10L excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 29 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 79.8 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for AUPU BF4-10L?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AUPU BF4-10L.
Why might a contractor swap AUPU BF4-10L for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AUPU BF4-10L lacks adequate reserve.
How does AUPU BF4-10L handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AUPU BF4-10L yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is AUPU BF4-10L quiet enough for a primary bedroom bathroom?
At 0.8 sones, AUPU BF4-10L operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is AUPU BF4-10L energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can AUPU BF4-10L pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU BF4-10L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU BF4-10L?
AUPU BF4-10L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU BF4-10L's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU BF4-10L's safe coverage footprint from 50 sq ft to 44 sq ft.
Can AUPU BF4-10L serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: AUPU BF4-10L supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)