The VOTATEC VO-FN4W26-AC-100 (VO-FN4W26-AC-100) moves 100 CFM at 0.1 in. w.g. (85 CFM at 0.25 in. w.g.), registers #239 of 607 in quietness (0.9 sones), and delivers 3.9 CFM/W efficacy, sizing bathrooms up to 85 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VOTATEC VO-FN4W26-AC-100 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 85 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 85.0% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does VOTATEC VO-FN4W26-AC-100 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 85 CFM out of 100 CFM (85.0% retention, 2.7 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms VOTATEC VO-FN4W26-AC-100 (series: VO-FN4W26-AC-100) under PD #4439172 (4 models registered, 2025-05-23). Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Wintek BPT15B-100H1 (100.0 CFM) and Nektra 33003853 (100.0 CFM).
Where does VOTATEC VO-FN4W26-AC-100 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.9 sones against all 1,145 EPA listings.
How does duct geometry alter VOTATEC VO-FN4W26-AC-100 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to VOTATEC VO-FN4W26-AC-100?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for VOTATEC VO-FN4W26-AC-100 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VOTATEC (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | VO-FN4W26-AC-100 / VO-FN4W26-AC-100 | PD ID 4439172 (Qualified 2025-05-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (85 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can VOTATEC VO-FN4W26-AC-100 ventilate safely?
Sizing outputs below convert VOTATEC VO-FN4W26-AC-100 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 85 sq ft | 1 CFM/sq ft @ 85 CFM |
| Tall Bath (9-ft Ceiling) | Up to 75 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 35 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match VOTATEC VO-FN4W26-AC-100 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Wintek BPT15B-100H1 | 100 / 85 CFM | 0.9 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Nektra 33003853 | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Nektra Pro 33003856 | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Wintek BPT15B-100H2 | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| S&P PC110XP | 100 / 83.8 CFM | 0.9 sones (Same) | 3.6 CFM/W | 4 in. diameter |
Will VOTATEC VO-FN4W26-AC-100 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether VOTATEC VO-FN4W26-AC-100 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Where should contractors skip VOTATEC VO-FN4W26-AC-100 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for VOTATEC VO-FN4W26-AC-100 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 35 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 85 sq ft with 8-ft ceilings (75 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern VOTATEC VO-FN4W26-AC-100?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting VOTATEC VO-FN4W26-AC-100.
What duct and room conditions disqualify VOTATEC VO-FN4W26-AC-100?
Rule out VOTATEC VO-FN4W26-AC-100 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke VOTATEC VO-FN4W26-AC-100 capacity?
Because static drag at 0.25 in. w.g. lowers VOTATEC VO-FN4W26-AC-100 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is VOTATEC VO-FN4W26-AC-100 compared with a standard 3.0 sone builder fan?
Tested at 0.9 sones, VOTATEC VO-FN4W26-AC-100 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does VOTATEC VO-FN4W26-AC-100 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, VOTATEC VO-FN4W26-AC-100 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can VOTATEC VO-FN4W26-AC-100 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VOTATEC VO-FN4W26-AC-100's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VOTATEC VO-FN4W26-AC-100?
VOTATEC VO-FN4W26-AC-100 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VOTATEC VO-FN4W26-AC-100's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VOTATEC VO-FN4W26-AC-100's safe coverage footprint from 50 sq ft to 44 sq ft.
How does VOTATEC VO-FN4W26-AC-100 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), VOTATEC VO-FN4W26-AC-100 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)