Homeowners specifying Nektra Pro 33003856 gain 100 CFM at 0.1 in. w.g. (84.1 CFM at 0.25 in. w.g.) where it registers #239 of 607 in quietness (0.9 sones) and delivers 4.1 CFM/W efficacy, venting bathrooms up to 84 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nektra Pro 33003856 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 84.1 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 4.1 CFM/W (#821/1,145)
- Static Retention
- 84.1% @ 0.25"
- Motor Draw
- 24.4 W (8.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Nektra Pro 33003856 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.1 CFM at 0.25 in. w.g. (84.1% retention, 3.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Nektra Pro's 2-unit lineup, 33003856 (series: 33003856) carries PD #4498414 dating to 2025-09-05. Lighting kit: No. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Nektra 33003853 (100.0 CFM) and Wintek BPT15B-100H2 (100.0 CFM).
What acoustic percentile does Nektra Pro 33003856 occupy among 1,145 bath blowers?
Inspect how Nektra Pro 33003856 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Nektra Pro 33003856 best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Nektra Pro 33003856 housings.
Where do Nektra Pro 33003856 acoustic and static metrics stand?
Compare Nektra Pro 33003856 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Nektra Pro (2 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 33003856 / 33003856 | PD ID 4498414 (Qualified 2025-09-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (84.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Nektra Pro 33003856 handle taller ceilings or walk-in tub steam?
Evaluate how Nektra Pro 33003856 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 74 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Nektra Pro 33003856?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nektra 33003853 | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Wintek BPT15B-100H2 | 100 / 84.1 CFM | 0.9 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| VOTATEC VO-FN4W26-AC-100 | 100 / 85 CFM | 0.9 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Wintek BPT15B-100H1 | 100 / 85 CFM | 0.9 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| ARTIKA FAB-BRLU-C1 | 100 / 95.3 CFM | 0.9 sones (Same) | 4.5 CFM/W | 4 in. diameter |
Is Nektra Pro 33003856 sized right for your shower or tub room?
Check whether Nektra Pro 33003856 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Which bath layouts should avoid specifying Nektra Pro 33003856?
Match Nektra Pro 33003856 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 34 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Moisture load fits 84.1 CFM net static output
- Optimal use: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Nektra Pro 33003856?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Nektra Pro 33003856.
Where does Nektra Pro 33003856 sit on acoustic comfort for senior homeowners?
Measuring 0.9 sones, Nektra Pro 33003856 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Nektra Pro 33003856 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Nektra Pro 33003856 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Nektra Pro 33003856 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nektra Pro 33003856's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Nektra Pro 33003856?
Nektra Pro 33003856 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Nektra Pro 33003856's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nektra Pro 33003856's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Nektra Pro 33003856 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Nektra Pro 33003856 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Nektra Pro 33003856 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Nektra Pro 33003856.
What happens to Nektra Pro 33003856 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Nektra Pro 33003856 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)