ARTIKA FAB-BRLU-C1 Exhaust Fan Specifications

ENERGY STAR PD #2402462 · Bathroom/Utility Room · Qualified 2022-08-26
Verified Specification Summary

Certified by EPA ENERGY STAR, ARTIKA FAB-BRLU-C1 delivers 100 CFM free-air (95.3 CFM at 0.25 in. w.g.) and registers #239 of 607 in quietness (0.9 sones) and delivers 4.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 95 sq ft (8-ft height) or 84 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ARTIKA FAB-BRLU-C1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 95.3 CFM
Noise @ 0.1"
0.9 sones (#239/607)
Efficacy Rank
4.5 CFM/W (#632/1,145)
Static Retention
95.3% @ 0.25"
Motor Draw
22.2 W (8.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does ARTIKA FAB-BRLU-C1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.3 CFM out of 100 CFM (95.3% retention, 7.6 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

ARTIKA maintains 1 active ENERGY STAR blower; FAB-BRLU-C1 (series: FAB-BRLU-C1) (PD #2402462) gained qualification on 2022-08-26. Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.2 watts, about 8.1 kWh/yr (~$1.30/yr at $0.16/kWh) for 1 hr/day shower timers or 194.5 kWh/yr (~$31.12/yr) continuously. Closest competing matches include Nektra 33003853 (100.0 CFM) and Nektra Pro 33003856 (100.0 CFM).

How noisy is ARTIKA FAB-BRLU-C1 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while ARTIKA FAB-BRLU-C1 measures 0.9 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.9 sone: 0.9 sones (43rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.9 sone: 0.9 sones (P43)

Why does rigid 4 in. diameter ducting protect ARTIKA FAB-BRLU-C1 airflow?

Connecting ARTIKA FAB-BRLU-C1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify ARTIKA FAB-BRLU-C1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for ARTIKA FAB-BRLU-C1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share ARTIKA (1 model) ENERGY STAR Certified Partner
Model Number & Series FAB-BRLU-C1 / FAB-BRLU-C1 PD ID 2402462 (Qualified 2022-08-26)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (95.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.9 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit ARTIKA FAB-BRLU-C1?

Calculated coverage metrics translate ARTIKA FAB-BRLU-C1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for ARTIKA FAB-BRLU-C1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 95 sq ft1 CFM/sq ft @ 95.3 CFM
Tall Bath (9-ft Ceiling)Up to 84 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 45 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.1 kWh/yr (~$1.30/yr)22.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2194.5 kWh/yr (~$31.12/yr)22.2 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to ARTIKA FAB-BRLU-C1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Nektra 33003853 100 / 84.1 CFM 0.9 sones (Same) 4.1 CFM/W 4 in. diameter
Nektra Pro 33003856 100 / 84.1 CFM 0.9 sones (Same) 4.1 CFM/W 4 in. diameter
Wintek BPT15B-100H2 100 / 84.1 CFM 0.9 sones (Same) 4.1 CFM/W 4 in. diameter
VOTATEC VO-FN4W26-AC-100 100 / 85 CFM 0.9 sones (Same) 3.9 CFM/W 4 in. diameter
Wintek BPT15B-100H1 100 / 85 CFM 0.9 sones (Same) 3.9 CFM/W 4 in. diameter

Does ARTIKA FAB-BRLU-C1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check ARTIKA FAB-BRLU-C1 percentage capacity without sending data.

When does ARTIKA FAB-BRLU-C1 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering ARTIKA FAB-BRLU-C1.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 45 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 95.3 CFM net static output
  • Target scenario: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for ARTIKA FAB-BRLU-C1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around ARTIKA FAB-BRLU-C1.

Does running ARTIKA FAB-BRLU-C1 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of ARTIKA FAB-BRLU-C1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can ARTIKA FAB-BRLU-C1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ARTIKA FAB-BRLU-C1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing ARTIKA FAB-BRLU-C1?

ARTIKA FAB-BRLU-C1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change ARTIKA FAB-BRLU-C1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ARTIKA FAB-BRLU-C1's safe coverage footprint from 50 sq ft to 44 sq ft.

Is ARTIKA FAB-BRLU-C1 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), ARTIKA FAB-BRLU-C1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than ARTIKA FAB-BRLU-C1?

Do not force ARTIKA FAB-BRLU-C1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does ARTIKA FAB-BRLU-C1 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, ARTIKA FAB-BRLU-C1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will ARTIKA FAB-BRLU-C1 disturb adjacent bedrooms during night use?

Acoustic measurement places ARTIKA FAB-BRLU-C1 at 0.9 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories