Ortech OD-1109PB Exhaust Fan Specifications

ENERGY STAR PD #2402464 · Bathroom/Utility Room · Qualified 2022-10-07
Verified Specification Summary

In EPA dataset 8dv7-nngq, Ortech OD-1109PB tests at 110 CFM free discharge (101.6 CFM at 0.25 in. w.g.) and registers #239 of 607 in quietness (0.9 sones) and delivers 4.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 101 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OD-1109PB Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 101.6 CFM
Noise @ 0.1"
0.9 sones (#239/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
92.4% @ 0.25"
Motor Draw
25.6 W (9.3 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech OD-1109PB vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 101.6 CFM out of 110 CFM (92.4% retention, 4.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Ortech maintains 27 active ENERGY STAR blowers; OD-1109PB (series: OD) (PD #2402464) gained qualification on 2022-10-07. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Cyclone ESCBP110 (110.0 CFM) and ACIQ AEP110 (110.0 CFM).

Does Ortech OD-1109PB fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Ortech OD-1109PB at 0.9 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.9 sone: 0.9 sones (43rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.9 sone: 0.9 sones (P43)

Why avoid unvented attic termination with Ortech OD-1109PB?

Under ASHRAE 62.2 best practice, Ortech OD-1109PB needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Ortech OD-1109PB?

Before cutting ceiling drywall or sizing attic transitions for Ortech OD-1109PB, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series OD-1109PB / OD PD ID 2402464 (Qualified 2022-10-07)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (101.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.9 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Ortech OD-1109PB?

Bathroom ventilation sizing below maps Ortech OD-1109PB motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Ortech OD-1109PB
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 101 sq ft1 CFM/sq ft @ 101.6 CFM
Tall Bath (9-ft Ceiling)Up to 90 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 51 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.3 kWh/yr (~$1.49/yr)25.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2224.3 kWh/yr (~$35.89/yr)25.6 W x 8,760 hrs / 1,000

What peer models sit nearest Ortech OD-1109PB in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Ortech OD-1109PB.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Cyclone ESCBP110 110 / 101.6 CFM 0.9 sones (Same) 4.3 CFM/W 6 in. diameter
ACIQ AEP110 110 / 94.2 CFM 0.9 sones (Same) 4.2 CFM/W 6 in. diameter
Canarm CEP110 110 / 94.2 CFM 0.9 sones (Same) 4.2 CFM/W 6 in. diameter
AERO PURE ABF110L6W 110 / 88.3 CFM 0.9 sones (Same) 4.4 CFM/W 4 in. diameter
AUPU AV11AL3 110 / 88.3 CFM 0.9 sones (Same) 4.4 CFM/W 4 in. diameter

What percentage of room demand does Ortech OD-1109PB cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Ortech OD-1109PB tested delivery.

Does Ortech OD-1109PB suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Ortech OD-1109PB for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 101.6 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 0.9 sones up to 101 sq ft
  • Best application: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Ortech OD-1109PB?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Ortech OD-1109PB.

How many kWh per year does Ortech OD-1109PB add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Ortech OD-1109PB averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Ortech OD-1109PB pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OD-1109PB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech OD-1109PB?

Ortech OD-1109PB features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech OD-1109PB's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OD-1109PB's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Ortech OD-1109PB pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Ortech OD-1109PB easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Ortech OD-1109PB in a bathroom remodel?

Avoid specifying Ortech OD-1109PB in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Ortech OD-1109PB airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Ortech OD-1109PB achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Ortech OD-1109PB occupy in EPA filings?

With 0.9 sones at 0.1 in. w.g., Ortech OD-1109PB operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories