In EPA dataset 8dv7-nngq, Ortech OD-1109PB tests at 110 CFM free discharge (101.6 CFM at 0.25 in. w.g.) and registers #239 of 607 in quietness (0.9 sones) and delivers 4.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 101 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OD-1109PB Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 101.6 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 92.4% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Ortech OD-1109PB vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 101.6 CFM out of 110 CFM (92.4% retention, 4.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Ortech maintains 27 active ENERGY STAR blowers; OD-1109PB (series: OD) (PD #2402464) gained qualification on 2022-10-07. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Cyclone ESCBP110 (110.0 CFM) and ACIQ AEP110 (110.0 CFM).
Does Ortech OD-1109PB fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Ortech OD-1109PB at 0.9 sones.
Why avoid unvented attic termination with Ortech OD-1109PB?
Under ASHRAE 62.2 best practice, Ortech OD-1109PB needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Ortech OD-1109PB?
Before cutting ceiling drywall or sizing attic transitions for Ortech OD-1109PB, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | OD-1109PB / OD | PD ID 2402464 (Qualified 2022-10-07) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (101.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Ortech OD-1109PB?
Bathroom ventilation sizing below maps Ortech OD-1109PB motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 101 sq ft | 1 CFM/sq ft @ 101.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 90 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 51 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
What peer models sit nearest Ortech OD-1109PB in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Ortech OD-1109PB.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Cyclone ESCBP110 | 110 / 101.6 CFM | 0.9 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| ACIQ AEP110 | 110 / 94.2 CFM | 0.9 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Canarm CEP110 | 110 / 94.2 CFM | 0.9 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| AERO PURE ABF110L6W | 110 / 88.3 CFM | 0.9 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AUPU AV11AL3 | 110 / 88.3 CFM | 0.9 sones (Same) | 4.4 CFM/W | 4 in. diameter |
What percentage of room demand does Ortech OD-1109PB cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Ortech OD-1109PB tested delivery.
Does Ortech OD-1109PB suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Ortech OD-1109PB for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 101.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 0.9 sones up to 101 sq ft
- Best application: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Ortech OD-1109PB?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Ortech OD-1109PB.
How many kWh per year does Ortech OD-1109PB add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Ortech OD-1109PB averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Ortech OD-1109PB pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OD-1109PB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech OD-1109PB?
Ortech OD-1109PB features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech OD-1109PB's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OD-1109PB's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Ortech OD-1109PB pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Ortech OD-1109PB easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Ortech OD-1109PB in a bathroom remodel?
Avoid specifying Ortech OD-1109PB in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Ortech OD-1109PB airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Ortech OD-1109PB achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Ortech OD-1109PB occupy in EPA filings?
With 0.9 sones at 0.1 in. w.g., Ortech OD-1109PB operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)