Rated for 110 CFM open-air (101.6 CFM at 0.25 in. w.g.), Cyclone ESCBP110 registers #239 of 607 in quietness (0.9 sones) and delivers 4.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 101 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Cyclone ESCBP110 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 101.6 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 92.4% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Cyclone ESCBP110 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 101.6 CFM out of 110 CFM (92.4% retention, 4.7 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Cyclone maintains 17 active ENERGY STAR blowers; ESCBP110 (series: ESCBP) (PD #2409639) gained qualification on 2023-02-24. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Ortech OD-1109PB (110.0 CFM) and ACIQ AEP110 (110.0 CFM).
How does Cyclone ESCBP110 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Cyclone ESCBP110 (0.9 sones).
How do flex elbows choke Cyclone ESCBP110 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Cyclone ESCBP110 moving full rated CFM.
Does Cyclone ESCBP110 meet residential exhaust fan code specs?
Inspect Cyclone ESCBP110 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Cyclone (17 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ESCBP110 / ESCBP | PD ID 2409639 (Qualified 2023-02-24) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (101.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Cyclone ESCBP110 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Cyclone ESCBP110 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 101 sq ft | 1 CFM/sq ft @ 101.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 90 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 51 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
Which competing models share Cyclone ESCBP110 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Ortech OD-1109PB | 110 / 101.6 CFM | 0.9 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| ACIQ AEP110 | 110 / 94.2 CFM | 0.9 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Canarm CEP110 | 110 / 94.2 CFM | 0.9 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| AERO PURE ABF110L6W | 110 / 88.3 CFM | 0.9 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AUPU AV11AL3 | 110 / 88.3 CFM | 0.9 sones (Same) | 4.4 CFM/W | 4 in. diameter |
How much airflow margin does Cyclone ESCBP110 give your bath?
Run a quick local room-volume check for Cyclone ESCBP110 by entering square footage and ceiling height to spot under-vented steam risks early.
Where should contractors skip Cyclone ESCBP110 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Cyclone ESCBP110 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 51 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 101 sq ft with 8-ft ceilings (90 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Cyclone ESCBP110?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Cyclone ESCBP110.
Will long attic ducting choke Cyclone ESCBP110 capacity?
Because static drag at 0.25 in. w.g. lowers Cyclone ESCBP110 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Cyclone ESCBP110 compared with a standard 3.0 sone builder fan?
Tested at 0.9 sones, Cyclone ESCBP110 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Cyclone ESCBP110 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Cyclone ESCBP110 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Cyclone ESCBP110 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Cyclone ESCBP110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Cyclone ESCBP110?
Cyclone ESCBP110 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Cyclone ESCBP110's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Cyclone ESCBP110's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Cyclone ESCBP110 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Cyclone ESCBP110 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Cyclone ESCBP110?
Rule out Cyclone ESCBP110 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)