In EPA dataset 8dv7-nngq, AERO PURE ABF110L6W tests at 110 CFM free discharge (88.3 CFM at 0.25 in. w.g.) and registers #239 of 607 in quietness (0.9 sones) and delivers 4.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 88 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF110L6W Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 88.3 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 80.3% @ 0.25"
- Motor Draw
- 25.0 W (9.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AERO PURE ABF110L6W vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 88.3 CFM at 0.25 in. w.g. (80.3% retention, 7.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places ABF110L6W (series: ABF110L) (PD #4587267) among 14 AERO PURE entries qualified through 2026-04-08. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include AUPU AV11AL3 (110.0 CFM) and AUPU AV11A1 (110.0 CFM).
Does AERO PURE ABF110L6W fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with AERO PURE ABF110L6W at 0.9 sones.
Why avoid unvented attic termination with AERO PURE ABF110L6W?
Under ASHRAE 62.2 best practice, AERO PURE ABF110L6W needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern AERO PURE ABF110L6W?
Before cutting ceiling drywall or sizing attic transitions for AERO PURE ABF110L6W, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AERO PURE (14 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ABF110L6W / ABF110L | PD ID 4587267 (Qualified 2026-04-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (88.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit AERO PURE ABF110L6W?
Bathroom ventilation sizing below maps AERO PURE ABF110L6W motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 88 sq ft | 1 CFM/sq ft @ 88.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 78 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 38 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.1 kWh/yr (~$1.46/yr) | 25.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 219.0 kWh/yr (~$35.04/yr) | 25.0 W x 8,760 hrs / 1,000 |
What peer models sit nearest AERO PURE ABF110L6W in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to AERO PURE ABF110L6W.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| AUPU AV11AL3 | 110 / 88.3 CFM | 0.9 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AUPU AV11A1 | 110 / 87.7 CFM | 0.9 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| AUPU AV11A2 | 110 / 87.7 CFM | 0.9 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Cyclone ESCBP110 | 110 / 101.6 CFM | 0.9 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| Ortech OD-1109PB | 110 / 101.6 CFM | 0.9 sones (Same) | 4.3 CFM/W | 6 in. diameter |
What percentage of room demand does AERO PURE ABF110L6W cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against AERO PURE ABF110L6W tested delivery.
Which bath layouts should avoid specifying AERO PURE ABF110L6W?
Match AERO PURE ABF110L6W directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 88.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 0.9 sones up to 88 sq ft
- Optimal use: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for AERO PURE ABF110L6W?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing AERO PURE ABF110L6W.
What bathroom square footage can AERO PURE ABF110L6W ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), AERO PURE ABF110L6W covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does AERO PURE ABF110L6W run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with AERO PURE ABF110L6W.
What happens to AERO PURE ABF110L6W CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, AERO PURE ABF110L6W moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does AERO PURE ABF110L6W sit on acoustic comfort for senior homeowners?
Measuring 0.9 sones, AERO PURE ABF110L6W operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does AERO PURE ABF110L6W cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running AERO PURE ABF110L6W 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can AERO PURE ABF110L6W pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF110L6W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AERO PURE ABF110L6W?
AERO PURE ABF110L6W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AERO PURE ABF110L6W's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF110L6W's safe coverage footprint from 50 sq ft to 44 sq ft.