AERO PURE ABF110G15W Exhaust Fan Specifications

ENERGY STAR PD #2331229 · Bathroom/Utility Room · Qualified 2018-12-07
Verified Specification Summary

Tested under HVI protocols, the AERO PURE ABF110G15W exhaust unit achieves 110 CFM at 0.1 in. w.g. (87.7 CFM at 0.25 in. w.g.), registers #239 of 607 in quietness (0.9 sones) and delivers 4.5 CFM/W efficacy, covering standard baths up to 87 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF110G15W Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 87.7 CFM
Noise @ 0.1"
0.9 sones (#239/607)
Efficacy Rank
4.5 CFM/W (#632/1,145)
Static Retention
79.7% @ 0.25"
Motor Draw
24.4 W (8.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AERO PURE ABF110G15W vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 87.7 CFM at 0.25 in. w.g. (79.7% retention, 8.0 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms AERO PURE ABF110G15W (series: ABF) under PD #2331229 (14 models registered, 2018-12-07). Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include AUPU AV11A1 (110.0 CFM) and AUPU AV11A2 (110.0 CFM).

Where do AERO PURE ABF110G15W sones rank across EPA ENERGY STAR fans?

Comparing AERO PURE ABF110G15W (0.9 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.9 sone: 0.9 sones (43rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.9 sone: 0.9 sones (P43)

What attic duct routing preserves AERO PURE ABF110G15W CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AERO PURE ABF110G15W, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does AERO PURE ABF110G15W measure up on airflow and noise ratings?

Each row below breaks down AERO PURE ABF110G15W certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AERO PURE (14 models) ENERGY STAR Certified Partner
Model Number & Series ABF110G15W / ABF PD ID 2331229 (Qualified 2018-12-07)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (87.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.9 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect AERO PURE ABF110G15W CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for AERO PURE ABF110G15W
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 87 sq ft1 CFM/sq ft @ 87.7 CFM
Tall Bath (9-ft Ceiling)Up to 77 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 37 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.9 kWh/yr (~$1.42/yr)24.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2213.7 kWh/yr (~$34.19/yr)24.4 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against AERO PURE ABF110G15W?

Compare AERO PURE ABF110G15W side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
AUPU AV11A1 110 / 87.7 CFM 0.9 sones (Same) 4.5 CFM/W 4 in. diameter
AUPU AV11A2 110 / 87.7 CFM 0.9 sones (Same) 4.5 CFM/W 4 in. diameter
AUPU AV11AL3 110 / 88.3 CFM 0.9 sones (Same) 4.4 CFM/W 4 in. diameter
Cyclone ESCBP110 110 / 101.6 CFM 0.9 sones (Same) 4.3 CFM/W 6 in. diameter
Ortech OD-1109PB 110 / 101.6 CFM 0.9 sones (Same) 4.3 CFM/W 6 in. diameter

Can you size AERO PURE ABF110G15W for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AERO PURE ABF110G15W verified capacity.

What plumbing or duct constraints rule out AERO PURE ABF110G15W?

Compare where AERO PURE ABF110G15W excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 87.7 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 0.9 sones up to 87 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to AERO PURE ABF110G15W?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AERO PURE ABF110G15W.

How does AERO PURE ABF110G15W handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AERO PURE ABF110G15W yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is AERO PURE ABF110G15W quiet enough for a primary bedroom bathroom?

At 0.9 sones, AERO PURE ABF110G15W operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is AERO PURE ABF110G15W energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can AERO PURE ABF110G15W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF110G15W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AERO PURE ABF110G15W?

AERO PURE ABF110G15W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AERO PURE ABF110G15W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF110G15W's safe coverage footprint from 50 sq ft to 44 sq ft.

Can AERO PURE ABF110G15W serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: AERO PURE ABF110G15W supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap AERO PURE ABF110G15W for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AERO PURE ABF110G15W lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)