AUPU AV11AL3 Exhaust Fan Specifications

ENERGY STAR PD #2839028 · Bathroom/Utility Room · Qualified 2023-12-01
Verified Specification Summary

Tested under HVI protocols, the AUPU AV11AL3 exhaust unit achieves 110 CFM at 0.1 in. w.g. (88.3 CFM at 0.25 in. w.g.), registers #239 of 607 in quietness (0.9 sones) and delivers 4.4 CFM/W efficacy, covering standard baths up to 88 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU AV11AL3 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 88.3 CFM
Noise @ 0.1"
0.9 sones (#239/607)
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
80.3% @ 0.25"
Motor Draw
25.0 W (9.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AUPU AV11AL3 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 88.3 CFM at 0.25 in. w.g. (80.3% retention, 7.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside AUPU's 35-unit lineup, AV11AL3 (series: AV) carries PD #2839028 dating to 2023-12-01. Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.0 watts, about 9.1 kWh/yr (~$1.46/yr at $0.16/kWh) for 1 hr/day shower timers or 219.0 kWh/yr (~$35.04/yr) continuously. Closest competing matches include AERO PURE ABF110L6W (110.0 CFM) and AERO PURE ABF110G15W (110.0 CFM).

Where do AUPU AV11AL3 sones rank across EPA ENERGY STAR fans?

Comparing AUPU AV11AL3 (0.9 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.9 sone: 0.9 sones (43rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.9 sone: 0.9 sones (P43)

What attic duct routing preserves AUPU AV11AL3 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AUPU AV11AL3, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does AUPU AV11AL3 measure up on airflow and noise ratings?

Each row below breaks down AUPU AV11AL3 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AUPU (35 models) ENERGY STAR Certified Partner
Model Number & Series AV11AL3 / AV PD ID 2839028 (Qualified 2023-12-01)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (88.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.9 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect AUPU AV11AL3 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for AUPU AV11AL3
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 88 sq ft1 CFM/sq ft @ 88.3 CFM
Tall Bath (9-ft Ceiling)Up to 78 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 38 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.1 kWh/yr (~$1.46/yr)25.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2219.0 kWh/yr (~$35.04/yr)25.0 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against AUPU AV11AL3?

Compare AUPU AV11AL3 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
AERO PURE ABF110L6W 110 / 88.3 CFM 0.9 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF110G15W 110 / 87.7 CFM 0.9 sones (Same) 4.5 CFM/W 4 in. diameter
Cyclone ESCBP110 110 / 101.6 CFM 0.9 sones (Same) 4.3 CFM/W 6 in. diameter
Ortech OD-1109PB 110 / 101.6 CFM 0.9 sones (Same) 4.3 CFM/W 6 in. diameter
ACIQ AEP110 110 / 94.2 CFM 0.9 sones (Same) 4.2 CFM/W 6 in. diameter

Can you size AUPU AV11AL3 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AUPU AV11AL3 verified capacity.

What plumbing or duct constraints rule out AUPU AV11AL3?

Compare where AUPU AV11AL3 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 88.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 0.9 sones up to 88 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to AUPU AV11AL3?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AUPU AV11AL3.

Why might a contractor swap AUPU AV11AL3 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AUPU AV11AL3 lacks adequate reserve.

How does AUPU AV11AL3 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AUPU AV11AL3 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is AUPU AV11AL3 quiet enough for a primary bedroom bathroom?

At 0.9 sones, AUPU AV11AL3 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is AUPU AV11AL3 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can AUPU AV11AL3 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU AV11AL3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AUPU AV11AL3?

AUPU AV11AL3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AUPU AV11AL3's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU AV11AL3's safe coverage footprint from 50 sq ft to 44 sq ft.

Can AUPU AV11AL3 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: AUPU AV11AL3 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)