ACIQ AEP110 Exhaust Fan Specifications

ENERGY STAR PD #3629726 · Bathroom/Utility Room · Qualified 2024-09-27
Verified Specification Summary

Rated for 110 CFM open-air (94.2 CFM at 0.25 in. w.g.), ACIQ AEP110 registers #239 of 607 in quietness (0.9 sones) and delivers 4.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 94 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside ACIQ AEP110 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 94.2 CFM
Noise @ 0.1"
0.9 sones (#239/607)
Efficacy Rank
4.2 CFM/W (#774/1,145)
Static Retention
85.6% @ 0.25"
Motor Draw
26.2 W (9.6 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does ACIQ AEP110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 94.2 CFM out of 110 CFM (85.6% retention, 2.1 pts lower retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places AEP110 (series: AEP) (PD #3629726) among 15 ACIQ entries qualified through 2024-09-27. Lighting kit: No. At 4.2 CFM/W (#774 of 1,145, below median tier among 1,145 rated models; more efficient than 28.4% of rated models, 0.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.2 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 229.5 kWh/yr (~$36.72/yr) continuously. Closest competing matches include Canarm CEP110 (110.0 CFM) and Cyclone ESCBP110 (110.0 CFM).

How does ACIQ AEP110 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against ACIQ AEP110 (0.9 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.9 sone: 0.9 sones (43rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.9 sone: 0.9 sones (P43)

How do flex elbows choke ACIQ AEP110 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps ACIQ AEP110 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does ACIQ AEP110 meet residential exhaust fan code specs?

Inspect ACIQ AEP110 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share ACIQ (15 models) ENERGY STAR Certified Partner
Model Number & Series AEP110 / AEP PD ID 3629726 (Qualified 2024-09-27)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (94.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.9 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match ACIQ AEP110 airflow output?

Annual electricity figures and room square-footage ceilings below reflect ACIQ AEP110 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for ACIQ AEP110
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 94 sq ft1 CFM/sq ft @ 94.2 CFM
Tall Bath (9-ft Ceiling)Up to 83 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 44 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.6 kWh/yr (~$1.54/yr)26.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2229.5 kWh/yr (~$36.72/yr)26.2 W x 8,760 hrs / 1,000

Which competing models share ACIQ AEP110 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Canarm CEP110 110 / 94.2 CFM 0.9 sones (Same) 4.2 CFM/W 6 in. diameter
Cyclone ESCBP110 110 / 101.6 CFM 0.9 sones (Same) 4.3 CFM/W 6 in. diameter
Ortech OD-1109PB 110 / 101.6 CFM 0.9 sones (Same) 4.3 CFM/W 6 in. diameter
AERO PURE ABF110L6W 110 / 88.3 CFM 0.9 sones (Same) 4.4 CFM/W 4 in. diameter
AUPU AV11AL3 110 / 88.3 CFM 0.9 sones (Same) 4.4 CFM/W 4 in. diameter

How much airflow margin does ACIQ AEP110 give your bath?

Run a quick local room-volume check for ACIQ AEP110 by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip ACIQ AEP110 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for ACIQ AEP110 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 44 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 94 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about ACIQ AEP110?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to ACIQ AEP110.

How much power does ACIQ AEP110 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, ACIQ AEP110 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can ACIQ AEP110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from ACIQ AEP110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing ACIQ AEP110?

ACIQ AEP110 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change ACIQ AEP110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing ACIQ AEP110's safe coverage footprint from 50 sq ft to 44 sq ft.

How does ACIQ AEP110 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), ACIQ AEP110 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify ACIQ AEP110?

Rule out ACIQ AEP110 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke ACIQ AEP110 capacity?

Because static drag at 0.25 in. w.g. lowers ACIQ AEP110 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is ACIQ AEP110 compared with a standard 3.0 sone builder fan?

Tested at 0.9 sones, ACIQ AEP110 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.