Rated for 120 CFM open-air (101.6 CFM at 0.25 in. w.g.), Ortech OD-1209PB registers #239 of 607 in quietness (0.9 sones) and delivers 4.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 101 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OD-1209PB Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 120 / 101.6 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 84.7% @ 0.25"
- Motor Draw
- 27.9 W (10.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Ortech OD-1209PB vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 120 CFM open-air to 101.6 CFM at 0.25 in. w.g. (84.7% retention, 3.0 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: Ortech registers 27 certified models, with SKU OD-1209PB (series: OD) (PD #2402465) certified since 2022-10-07. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.9 watts, about 10.2 kWh/yr (~$1.63/yr at $0.16/kWh) for 1 hr/day shower timers or 244.4 kWh/yr (~$39.10/yr) continuously. Closest competing matches include Cyclone ESCBP110 (110.0 CFM) and ACIQ AEP110 (110.0 CFM).
How does Ortech OD-1209PB acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Ortech OD-1209PB (0.9 sones).
How do flex elbows choke Ortech OD-1209PB at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Ortech OD-1209PB moving full rated CFM.
Does Ortech OD-1209PB meet residential exhaust fan code specs?
Inspect Ortech OD-1209PB mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | OD-1209PB / OD | PD ID 2402465 (Qualified 2022-10-07) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (101.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Ortech OD-1209PB airflow output?
Annual electricity figures and room square-footage ceilings below reflect Ortech OD-1209PB tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 101 sq ft | 1 CFM/sq ft @ 101.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 90 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 51 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 10.2 kWh/yr (~$1.63/yr) | 27.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 244.4 kWh/yr (~$39.10/yr) | 27.9 W x 8,760 hrs / 1,000 |
Which competing models share Ortech OD-1209PB airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Cyclone ESCBP110 | 110 / 101.6 CFM | 0.9 sones (Same) | 4.3 CFM/W | 6 in. diameter |
| ACIQ AEP110 | 110 / 94.2 CFM | 0.9 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| AERO PURE ABF110L6W | 110 / 88.3 CFM | 0.9 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AUPU AV11AL3 | 110 / 88.3 CFM | 0.9 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| Canarm CEP110 | 110 / 94.2 CFM | 0.9 sones (Same) | 4.2 CFM/W | 6 in. diameter |
How much airflow margin does Ortech OD-1209PB give your bath?
Run a quick local room-volume check for Ortech OD-1209PB by entering square footage and ceiling height to spot under-vented steam risks early.
Who should not install Ortech OD-1209PB in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Ortech OD-1209PB for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 51 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 101 sq ft with 8-ft ceilings (90 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Ortech OD-1209PB?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Ortech OD-1209PB.
Does Ortech OD-1209PB satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Ortech OD-1209PB clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Ortech OD-1209PB undersized or poorly matched for a bath renovation?
Skip Ortech OD-1209PB if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Ortech OD-1209PB CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Ortech OD-1209PB registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
How does Ortech OD-1209PB sound output compare to noisy contractor-grade fans?
Rated at 0.9 sones, Ortech OD-1209PB operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Ortech OD-1209PB?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Ortech OD-1209PB pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OD-1209PB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech OD-1209PB?
Ortech OD-1209PB features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech OD-1209PB's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OD-1209PB's safe coverage footprint from 50 sq ft to 44 sq ft.