Homeowners specifying Air King AK150LS gain 150 CFM at 0.1 in. w.g. (124.4 CFM at 0.25 in. w.g.) where it registers #239 of 607 in quietness (0.9 sones) and delivers 4.5 CFM/W efficacy, venting bathrooms up to 124 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK150LS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 124.4 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 82.9% @ 0.25"
- Motor Draw
- 33.3 W (12.2 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Air King AK150LS vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 124.4 CFM at 0.25 in. w.g. (82.9% retention, 4.8 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #2397912 verifies AK150LS (series: Air King) under Air King (62 listed models, qualified 2022-06-24). Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Tech Drive TD-BF-19 (160.0 CFM) and VENTECHLATION VF-BF-06 (160.0 CFM).
What acoustic percentile does Air King AK150LS occupy among 1,145 bath blowers?
Inspect how Air King AK150LS positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Air King AK150LS best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Air King AK150LS housings.
Where do Air King AK150LS acoustic and static metrics stand?
Compare Air King AK150LS published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK150LS / Air King | PD ID 2397912 (Qualified 2022-06-24) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (124.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Air King AK150LS handle taller ceilings or walk-in tub steam?
Evaluate how Air King AK150LS scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 124 sq ft | 1 CFM/sq ft @ 124.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 74 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.2 kWh/yr (~$1.95/yr) | 33.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 291.7 kWh/yr (~$46.67/yr) | 33.3 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Air King AK150LS?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-19 | 160 / 138.2 CFM | 1.0 sones (+0.10) | 4.5 CFM/W | 6 in. diameter |
| VENTECHLATION VF-BF-06 | 160 / 138.2 CFM | 1.0 sones (+0.10) | 4.5 CFM/W | 6 in. diameter |
| OREiN OL1700376 | 160 / 152 CFM | 1.0 sones (+0.10) | 4.8 CFM/W | 6 in. diameter |
| Hampton Bay 7136-02 | 140 / 124.4 CFM | 1.0 sones (+0.10) | 3.9 CFM/W | 6 in. diameter |
| HomeWerks Worldwide 7136-02HW | 140 / 124.4 CFM | 1.0 sones (+0.10) | 3.9 CFM/W | 6 in. diameter |
Is Air King AK150LS sized right for your shower or tub room?
Check whether Air King AK150LS clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Who should not install Air King AK150LS in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Air King AK150LS for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 74 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 124.4 CFM net static output
- Primary match: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for Air King AK150LS?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Air King AK150LS.
How does Air King AK150LS sound output compare to noisy contractor-grade fans?
Rated at 0.9 sones, Air King AK150LS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Air King AK150LS?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Air King AK150LS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK150LS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King AK150LS?
Air King AK150LS features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King AK150LS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK150LS's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Air King AK150LS satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Air King AK150LS clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Air King AK150LS undersized or poorly matched for a bath renovation?
Skip Air King AK150LS if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Air King AK150LS CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Air King AK150LS registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)