The Tech Drive TD-BF-19 (TD) moves 160 CFM at 0.1 in. w.g. (138.2 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 4.5 CFM/W efficacy, sizing bathrooms up to 138 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-19 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 160 / 138.2 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 86.4% @ 0.25"
- Motor Draw
- 35.6 W (13.0 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Tech Drive TD-BF-19 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 138.2 CFM out of 160 CFM (86.4% retention, 1.3 pts lower retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Certification audit confirms Tech Drive TD-BF-19 (series: TD) under PD #4697594 (27 models registered, 2026-09-02). Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 35.6 watts, about 13.0 kWh/yr (~$2.08/yr at $0.16/kWh) for 1 hr/day shower timers or 311.9 kWh/yr (~$49.90/yr) continuously. Closest competing matches include VENTECHLATION VF-BF-06 (160.0 CFM) and OREiN OL1700376 (160.0 CFM).
Where does Tech Drive TD-BF-19 sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.
How does duct geometry alter Tech Drive TD-BF-19 static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Tech Drive TD-BF-19?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Tech Drive TD-BF-19 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-BF-19 / TD | PD ID 4697594 (Qualified 2026-09-02) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (138.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Tech Drive TD-BF-19 ventilate safely?
Sizing outputs below convert Tech Drive TD-BF-19 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 138 sq ft | 1 CFM/sq ft @ 138.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 122 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 88 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 13.0 kWh/yr (~$2.08/yr) | 35.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 311.9 kWh/yr (~$49.90/yr) | 35.6 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Tech Drive TD-BF-19 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| VENTECHLATION VF-BF-06 | 160 / 138.2 CFM | 1.0 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| OREiN OL1700376 | 160 / 152 CFM | 1.0 sones (Same) | 4.8 CFM/W | 6 in. diameter |
| Air King AK150LS | 150 / 124.4 CFM | 0.9 sones (-0.10) | 4.5 CFM/W | 6 in. diameter |
| Hampton Bay 7136-02 | 140 / 124.4 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| HomeWerks Worldwide 7136-02HW | 140 / 124.4 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |
Will Tech Drive TD-BF-19 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Tech Drive TD-BF-19 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Tech Drive TD-BF-19 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Tech Drive TD-BF-19 for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 88 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 138 sq ft with 8-ft ceilings (122 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern Tech Drive TD-BF-19?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Tech Drive TD-BF-19.
What electrical efficiency and runtime kWh define Tech Drive TD-BF-19?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Tech Drive TD-BF-19 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-19's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive TD-BF-19?
Tech Drive TD-BF-19 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive TD-BF-19's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-19's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Tech Drive TD-BF-19 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-19 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Tech Drive TD-BF-19 undersized or poorly matched for a bath renovation?
Skip Tech Drive TD-BF-19 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Tech Drive TD-BF-19 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Tech Drive TD-BF-19 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.
How does Tech Drive TD-BF-19 sound output compare to noisy contractor-grade fans?
Rated at 1.0 sones, Tech Drive TD-BF-19 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)