Rated for 150 CFM open-air (123.8 CFM at 0.25 in. w.g.), Utilitech 7116-02 registers #265 of 607 in quietness (1.0 sones) and delivers 8.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 123 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Utilitech 7116-02 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 123.8 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 8.1 CFM/W (#338/1,145)
- Static Retention
- 82.5% @ 0.25"
- Motor Draw
- 18.5 W (6.8 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Utilitech 7116-02 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 123.8 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Certification audit confirms Utilitech 7116-02 (series: Utilitech) under PD #2343326 (22 models registered, 2017-11-10). Lighting kit: Yes. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.5 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.1 kWh/yr (~$25.94/yr) continuously. Closest competing matches include KORA SBF160DC-MS (161.6 CFM) and ACIQ AEPD150SC (150.0 CFM).
How does Utilitech 7116-02 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Utilitech 7116-02 (1.0 sones).
How do flex elbows choke Utilitech 7116-02 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Utilitech 7116-02 moving full rated CFM.
Does Utilitech 7116-02 meet residential exhaust fan code specs?
Inspect Utilitech 7116-02 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Utilitech (22 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7116-02 / Utilitech | PD ID 2343326 (Qualified 2017-11-10) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (123.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Utilitech 7116-02 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Utilitech 7116-02 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 123 sq ft | 1 CFM/sq ft @ 123.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 110 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 73 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.8 kWh/yr (~$1.09/yr) | 18.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 162.1 kWh/yr (~$25.94/yr) | 18.5 W x 8,760 hrs / 1,000 |
Which competing models share Utilitech 7116-02 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| KORA SBF160DC-MS | 161.6 / N/A CFM | 1.3 sones (+0.30) | 8.7 CFM/W | 4 in. diameter |
| ACIQ AEPD150SC | 150 / 130.3 CFM | 0.9 sones (-0.10) | 11.4 CFM/W | 6 in. diameter |
| OREiN OL1700376 | 160 / 152 CFM | 1.0 sones (Same) | 4.8 CFM/W | 6 in. diameter |
| Air King AK150LS | 150 / 124.4 CFM | 0.9 sones (-0.10) | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-19 | 160 / 138.2 CFM | 1.0 sones (Same) | 4.5 CFM/W | 6 in. diameter |
How much airflow margin does Utilitech 7116-02 give your bath?
Run a quick local room-volume check for Utilitech 7116-02 by entering square footage and ceiling height to spot under-vented steam risks early.
Which bath layouts should avoid specifying Utilitech 7116-02?
Match Utilitech 7116-02 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Steam or walk-in tub room > 73 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 123 sq ft with 8-ft ceilings (110 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Utilitech 7116-02?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Utilitech 7116-02.
What does Utilitech 7116-02 cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Utilitech 7116-02 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Utilitech 7116-02 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Utilitech 7116-02's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Utilitech 7116-02?
Utilitech 7116-02 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Utilitech 7116-02's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Utilitech 7116-02's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Utilitech 7116-02 ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Utilitech 7116-02 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Utilitech 7116-02 run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Utilitech 7116-02.
What happens to Utilitech 7116-02 CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Utilitech 7116-02 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Utilitech 7116-02 sit on acoustic comfort for senior homeowners?
Measuring 1.0 sones, Utilitech 7116-02 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)