Skip to main content
Grant Estimator

KORA SBF160DC-MS Exhaust Fan Specifications

ENERGY STAR PD #2399645 · Bathroom/Utility Room · Qualified 2022-07-19
Verified Specification Summary

Homeowners specifying KORA SBF160DC-MS gain 161.6 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output) where it registers #397 of 607 in quietness (1.3 sones) and delivers 8.7 CFM/W efficacy, venting bathrooms up to 161 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KORA SBF160DC-MS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
161.6 / N/A CFM
Noise @ 0.1"
1.3 sones (#397/607)
Efficacy Rank
8.7 CFM/W (#306/1,145)
Static Retention
0.1" test only
Motor Draw
18.6 W (6.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does KORA SBF160DC-MS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.3 sones (#397 of 607 rated models, 0.30 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Free-discharge delivery reaches 161.6 CFM (#83 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: KORA registers 5 certified models, with SKU SBF160DC-MS (series: Ceiling insert Fan) (PD #2399645) certified since 2022-07-19. Lighting kit: No. At 8.7 CFM/W (#306 of 1,145, top 27.6% of 1,145 rated models, more efficient than 72.4% of rated models, 4.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include Utilitech 7116-02 (150.0 CFM) and ACIQ AEPD150SC (150.0 CFM).

What acoustic percentile does KORA SBF160DC-MS occupy among 1,145 bath blowers?

Inspect how KORA SBF160DC-MS positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.3 sone: 1.3 sones (67th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.3 sone: 1.3 sones (P67)

Which exterior damper path suits KORA SBF160DC-MS best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around KORA SBF160DC-MS housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do KORA SBF160DC-MS acoustic and static metrics stand?

Compare KORA SBF160DC-MS published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share KORA (5 models) ENERGY STAR Certified Partner
Model Number & Series SBF160DC-MS / Ceiling insert Fan PD ID 2399645 (Qualified 2022-07-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (161.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.3 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can KORA SBF160DC-MS handle taller ceilings or walk-in tub steam?

Evaluate how KORA SBF160DC-MS scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for KORA SBF160DC-MS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 161 sq ft1 CFM/sq ft @ 161.6 CFM
Tall Bath (9-ft Ceiling)Up to 143 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 111 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.8 kWh/yr (~$1.09/yr)18.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2162.9 kWh/yr (~$26.06/yr)18.6 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near KORA SBF160DC-MS?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7116-02 150 / 123.8 CFM 1.0 sones (-0.30) 8.1 CFM/W 6 in. diameter
ACIQ AEPD150SC 150 / 130.3 CFM 0.9 sones (-0.40) 11.4 CFM/W 6 in. diameter
OREiN OL1700376 160 / 152 CFM 1.0 sones (-0.30) 4.8 CFM/W 6 in. diameter
Broan QT150LE 150 / 126.1 CFM 1.5 sones (+0.20) 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones (+0.20) 4.5 CFM/W 6 in. diameter

Is KORA SBF160DC-MS sized right for your shower or tub room?

Check whether KORA SBF160DC-MS clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does KORA SBF160DC-MS suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying KORA SBF160DC-MS for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 111 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 161.6 CFM net static output
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for KORA SBF160DC-MS?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to KORA SBF160DC-MS.

What acoustic sone tier does KORA SBF160DC-MS occupy in EPA filings?

With 1.3 sones at 0.1 in. w.g., KORA SBF160DC-MS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does KORA SBF160DC-MS add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, KORA SBF160DC-MS averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can KORA SBF160DC-MS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KORA SBF160DC-MS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing KORA SBF160DC-MS?

KORA SBF160DC-MS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change KORA SBF160DC-MS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KORA SBF160DC-MS's safe coverage footprint from 50 sq ft to 44 sq ft.

Does KORA SBF160DC-MS pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), KORA SBF160DC-MS easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install KORA SBF160DC-MS in a bathroom remodel?

Avoid specifying KORA SBF160DC-MS in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut KORA SBF160DC-MS airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, KORA SBF160DC-MS achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories