Skip to main content
Grant Estimator

Air King AK110LS Exhaust Fan Specifications

ENERGY STAR PD #2248779 · Bathroom/Utility Room · Qualified 2015-09-01
Verified Specification Summary

In EPA dataset 8dv7-nngq, Air King AK110LS tests at 110 CFM free discharge (90.7 CFM at 0.25 in. w.g.) and registers #397 of 607 in quietness (1.3 sones) and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 90 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King AK110LS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 90.7 CFM
Noise @ 0.1"
1.3 sones (#397/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
82.5% @ 0.25"
Motor Draw
28.2 W (10.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King AK110LS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.3 sones (#397 of 607 rated models, 0.30 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 90.7 CFM at 0.25 in. w.g. (82.5% retention, 5.2 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Air King's 62-unit lineup, AK110LS (series: N/A) carries PD #2248779 dating to 2015-09-01. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 28.2 watts, about 10.3 kWh/yr (~$1.65/yr at $0.16/kWh) for 1 hr/day shower timers or 247.0 kWh/yr (~$39.52/yr) continuously. Closest competing matches include Anzzi EF-AZ102WH (110.0 CFM) and COSTWAY BPT14-24A-A-1 (110.0 CFM).

Does Air King AK110LS fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Air King AK110LS at 1.3 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.3 sone: 1.3 sones (67th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.3 sone: 1.3 sones (P67)

Why avoid unvented attic termination with Air King AK110LS?

Under ASHRAE 62.2 best practice, Air King AK110LS needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Air King AK110LS?

Before cutting ceiling drywall or sizing attic transitions for Air King AK110LS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series AK110LS / N/A PD ID 2248779 (Qualified 2015-09-01)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (90.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.3 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Air King AK110LS?

Bathroom ventilation sizing below maps Air King AK110LS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Air King AK110LS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 90 sq ft1 CFM/sq ft @ 90.7 CFM
Tall Bath (9-ft Ceiling)Up to 80 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 40 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.3 kWh/yr (~$1.65/yr)28.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2247.0 kWh/yr (~$39.52/yr)28.2 W x 8,760 hrs / 1,000

What peer models sit nearest Air King AK110LS in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Air King AK110LS.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Anzzi EF-AZ102WH 110 / 101.4 CFM 1.3 sones (Same) 4.3 CFM/W 4 in. diameter
COSTWAY BPT14-24A-A-1 110 / 97.5 CFM 1.2 sones (-0.10) 4.3 CFM/W 4 in. diameter
Nektra 3291028 110 / 98.7 CFM 1.2 sones (-0.10) 4.5 CFM/W 4 in. diameter
Win Air BPT14-24E 110 / 98.7 CFM 1.2 sones (-0.10) 4.5 CFM/W 4 in. diameter
BV BV-BF-02-PLUS 110 / 99 CFM 1.2 sones (-0.10) 4.8 CFM/W 4 in. diameter

What percentage of room demand does Air King AK110LS cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Air King AK110LS tested delivery.

What plumbing or duct constraints rule out Air King AK110LS?

Compare where Air King AK110LS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 90.7 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 1.3 sones up to 90 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Air King AK110LS?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Air King AK110LS.

Can Air King AK110LS serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Air King AK110LS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Air King AK110LS for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Air King AK110LS lacks adequate reserve.

How does Air King AK110LS handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Air King AK110LS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Air King AK110LS quiet enough for a primary bedroom bathroom?

At 1.3 sones, Air King AK110LS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Air King AK110LS energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Air King AK110LS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King AK110LS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King AK110LS?

Air King AK110LS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King AK110LS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King AK110LS's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories