Tested under HVI protocols, the Anzzi EF-AZ102WH exhaust unit achieves 110 CFM at 0.1 in. w.g. (101.4 CFM at 0.25 in. w.g.), registers #397 of 607 in quietness (1.3 sones) and delivers 4.3 CFM/W efficacy, covering standard baths up to 101 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Anzzi EF-AZ102WH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 101.4 CFM
- Noise @ 0.1"
- 1.3 sones (#397/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 92.2% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Anzzi EF-AZ102WH vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.3 sones (#397 of 607 rated models, 0.30 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 101.4 CFM out of 110 CFM (92.2% retention, 4.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Anzzi's 8-unit lineup, EF-AZ102WH (series: EF) carries PD #3423381 dating to 2024-03-15. Lighting kit: Yes. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Air King AK110LS (110.0 CFM) and COSTWAY BPT14-24A-A-1 (110.0 CFM).
Where do Anzzi EF-AZ102WH sones rank across EPA ENERGY STAR fans?
Comparing Anzzi EF-AZ102WH (1.3 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Anzzi EF-AZ102WH CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Anzzi EF-AZ102WH, preventing premature peeling paint and mold growth.
How does Anzzi EF-AZ102WH measure up on airflow and noise ratings?
Each row below breaks down Anzzi EF-AZ102WH certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Anzzi (8 models) | ENERGY STAR Certified Partner |
| Model Number & Series | EF-AZ102WH / EF | PD ID 3423381 (Qualified 2024-03-15) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (101.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.3 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Anzzi EF-AZ102WH CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 101 sq ft | 1 CFM/sq ft @ 101.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 90 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 51 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Anzzi EF-AZ102WH?
Compare Anzzi EF-AZ102WH side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Air King AK110LS | 110 / 90.7 CFM | 1.3 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| COSTWAY BPT14-24A-A-1 | 110 / 97.5 CFM | 1.2 sones (-0.10) | 4.3 CFM/W | 4 in. diameter |
| Nektra 3291028 | 110 / 98.7 CFM | 1.2 sones (-0.10) | 4.5 CFM/W | 4 in. diameter |
| Win Air BPT14-24E | 110 / 98.7 CFM | 1.2 sones (-0.10) | 4.5 CFM/W | 4 in. diameter |
| BV BV-BF-02-PLUS | 110 / 99 CFM | 1.2 sones (-0.10) | 4.8 CFM/W | 4 in. diameter |
Can you size Anzzi EF-AZ102WH for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Anzzi EF-AZ102WH verified capacity.
Who should not install Anzzi EF-AZ102WH in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Anzzi EF-AZ102WH for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 101.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 1.3 sones up to 101 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Anzzi EF-AZ102WH?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Anzzi EF-AZ102WH.
Does Anzzi EF-AZ102WH satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Anzzi EF-AZ102WH clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Anzzi EF-AZ102WH undersized or poorly matched for a bath renovation?
Skip Anzzi EF-AZ102WH if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Anzzi EF-AZ102WH CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Anzzi EF-AZ102WH registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Anzzi EF-AZ102WH sound output compare to noisy contractor-grade fans?
Rated at 1.3 sones, Anzzi EF-AZ102WH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Anzzi EF-AZ102WH?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Anzzi EF-AZ102WH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Anzzi EF-AZ102WH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Anzzi EF-AZ102WH?
Anzzi EF-AZ102WH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Anzzi EF-AZ102WH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Anzzi EF-AZ102WH's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)