Skip to main content
Grant Estimator

Anzzi EF-AZ102WH Exhaust Fan Specifications

ENERGY STAR PD #3423381 · Bathroom/Utility Room · Qualified 2024-03-15
Verified Specification Summary

Tested under HVI protocols, the Anzzi EF-AZ102WH exhaust unit achieves 110 CFM at 0.1 in. w.g. (101.4 CFM at 0.25 in. w.g.), registers #397 of 607 in quietness (1.3 sones) and delivers 4.3 CFM/W efficacy, covering standard baths up to 101 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Anzzi EF-AZ102WH Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 101.4 CFM
Noise @ 0.1"
1.3 sones (#397/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
92.2% @ 0.25"
Motor Draw
25.6 W (9.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Anzzi EF-AZ102WH vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.3 sones (#397 of 607 rated models, 0.30 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 101.4 CFM out of 110 CFM (92.2% retention, 4.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Anzzi's 8-unit lineup, EF-AZ102WH (series: EF) carries PD #3423381 dating to 2024-03-15. Lighting kit: Yes. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Air King AK110LS (110.0 CFM) and COSTWAY BPT14-24A-A-1 (110.0 CFM).

Where do Anzzi EF-AZ102WH sones rank across EPA ENERGY STAR fans?

Comparing Anzzi EF-AZ102WH (1.3 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.3 sone: 1.3 sones (67th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.3 sone: 1.3 sones (P67)

What attic duct routing preserves Anzzi EF-AZ102WH CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Anzzi EF-AZ102WH, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Anzzi EF-AZ102WH measure up on airflow and noise ratings?

Each row below breaks down Anzzi EF-AZ102WH certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Anzzi (8 models) ENERGY STAR Certified Partner
Model Number & Series EF-AZ102WH / EF PD ID 3423381 (Qualified 2024-03-15)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (101.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.3 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Anzzi EF-AZ102WH CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Anzzi EF-AZ102WH
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 101 sq ft1 CFM/sq ft @ 101.4 CFM
Tall Bath (9-ft Ceiling)Up to 90 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 51 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.3 kWh/yr (~$1.49/yr)25.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2224.3 kWh/yr (~$35.89/yr)25.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Anzzi EF-AZ102WH?

Compare Anzzi EF-AZ102WH side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Air King AK110LS 110 / 90.7 CFM 1.3 sones (Same) 3.9 CFM/W 4 in. diameter
COSTWAY BPT14-24A-A-1 110 / 97.5 CFM 1.2 sones (-0.10) 4.3 CFM/W 4 in. diameter
Nektra 3291028 110 / 98.7 CFM 1.2 sones (-0.10) 4.5 CFM/W 4 in. diameter
Win Air BPT14-24E 110 / 98.7 CFM 1.2 sones (-0.10) 4.5 CFM/W 4 in. diameter
BV BV-BF-02-PLUS 110 / 99 CFM 1.2 sones (-0.10) 4.8 CFM/W 4 in. diameter

Can you size Anzzi EF-AZ102WH for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Anzzi EF-AZ102WH verified capacity.

Who should not install Anzzi EF-AZ102WH in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Anzzi EF-AZ102WH for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 101.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 1.3 sones up to 101 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Anzzi EF-AZ102WH?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Anzzi EF-AZ102WH.

Does Anzzi EF-AZ102WH satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Anzzi EF-AZ102WH clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Anzzi EF-AZ102WH undersized or poorly matched for a bath renovation?

Skip Anzzi EF-AZ102WH if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Anzzi EF-AZ102WH CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Anzzi EF-AZ102WH registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Anzzi EF-AZ102WH sound output compare to noisy contractor-grade fans?

Rated at 1.3 sones, Anzzi EF-AZ102WH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Anzzi EF-AZ102WH?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Anzzi EF-AZ102WH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Anzzi EF-AZ102WH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Anzzi EF-AZ102WH?

Anzzi EF-AZ102WH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Anzzi EF-AZ102WH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Anzzi EF-AZ102WH's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories