Tested under HVI protocols, the BV BV-BF-02-PLUS exhaust unit achieves 110 CFM at 0.1 in. w.g. (99 CFM at 0.25 in. w.g.), registers #380 of 607 in quietness (1.2 sones) and delivers 4.8 CFM/W efficacy, covering standard baths up to 99 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside BV BV-BF-02-PLUS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 99 CFM
- Noise @ 0.1"
- 1.2 sones (#380/607)
- Efficacy Rank
- 4.8 CFM/W (#534/1,145)
- Static Retention
- 90.0% @ 0.25"
- Motor Draw
- 22.9 W (8.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does BV BV-BF-02-PLUS vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 110 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: BV registers 3 certified models, with SKU BV-BF-02-PLUS (series: BV-BF-02-PLUS) (PD #4008361) certified since 2025-03-07. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Valu+ BPT14-24TGHS (110.0 CFM) and Nektra 3291028 (110.0 CFM).
Where do BV BV-BF-02-PLUS sones rank across EPA ENERGY STAR fans?
Comparing BV BV-BF-02-PLUS (1.2 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves BV BV-BF-02-PLUS CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on BV BV-BF-02-PLUS, preventing premature peeling paint and mold growth.
How does BV BV-BF-02-PLUS measure up on airflow and noise ratings?
Each row below breaks down BV BV-BF-02-PLUS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | BV (3 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BV-BF-02-PLUS / BV-BF-02-PLUS | PD ID 4008361 (Qualified 2025-03-07) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (99 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect BV BV-BF-02-PLUS CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 99 sq ft | 1 CFM/sq ft @ 99 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 49 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against BV BV-BF-02-PLUS?
Compare BV BV-BF-02-PLUS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Valu+ BPT14-24TGHS | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Nektra 3291028 | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Win Air BPT14-24E | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| COSTWAY BPT14-24A-A-1 | 110 / 97.5 CFM | 1.2 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Loren Cook Company GC-222 | 115 / 85 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4.5 x 6 in. rectangular |
Can you size BV BV-BF-02-PLUS for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against BV BV-BF-02-PLUS verified capacity.
When does BV BV-BF-02-PLUS fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering BV BV-BF-02-PLUS.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 99 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 1.2 sones up to 99 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to BV BV-BF-02-PLUS?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for BV BV-BF-02-PLUS.
How much airflow does BV BV-BF-02-PLUS retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, BV BV-BF-02-PLUS produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will BV BV-BF-02-PLUS disturb adjacent bedrooms during night use?
Acoustic measurement places BV BV-BF-02-PLUS at 1.2 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running BV BV-BF-02-PLUS continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of BV BV-BF-02-PLUS draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can BV BV-BF-02-PLUS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from BV BV-BF-02-PLUS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing BV BV-BF-02-PLUS?
BV BV-BF-02-PLUS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change BV BV-BF-02-PLUS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing BV BV-BF-02-PLUS's safe coverage footprint from 50 sq ft to 44 sq ft.
Is BV BV-BF-02-PLUS code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), BV BV-BF-02-PLUS clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than BV BV-BF-02-PLUS?
Do not force BV BV-BF-02-PLUS into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)