BV BV-BF-02-PLUS Exhaust Fan Specifications

ENERGY STAR PD #4008361 · Bathroom/Utility Room · Qualified 2025-03-07
Verified Specification Summary

Tested under HVI protocols, the BV BV-BF-02-PLUS exhaust unit achieves 110 CFM at 0.1 in. w.g. (99 CFM at 0.25 in. w.g.), registers #380 of 607 in quietness (1.2 sones) and delivers 4.8 CFM/W efficacy, covering standard baths up to 99 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside BV BV-BF-02-PLUS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 99 CFM
Noise @ 0.1"
1.2 sones (#380/607)
Efficacy Rank
4.8 CFM/W (#534/1,145)
Static Retention
90.0% @ 0.25"
Motor Draw
22.9 W (8.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does BV BV-BF-02-PLUS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 110 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: BV registers 3 certified models, with SKU BV-BF-02-PLUS (series: BV-BF-02-PLUS) (PD #4008361) certified since 2025-03-07. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Valu+ BPT14-24TGHS (110.0 CFM) and Nektra 3291028 (110.0 CFM).

Where do BV BV-BF-02-PLUS sones rank across EPA ENERGY STAR fans?

Comparing BV BV-BF-02-PLUS (1.2 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.2 sone: 1.2 sones (65th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.2 sone: 1.2 sones (P65)

What attic duct routing preserves BV BV-BF-02-PLUS CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on BV BV-BF-02-PLUS, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does BV BV-BF-02-PLUS measure up on airflow and noise ratings?

Each row below breaks down BV BV-BF-02-PLUS certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share BV (3 models) ENERGY STAR Certified Partner
Model Number & Series BV-BF-02-PLUS / BV-BF-02-PLUS PD ID 4008361 (Qualified 2025-03-07)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (99 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.2 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect BV BV-BF-02-PLUS CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for BV BV-BF-02-PLUS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 99 sq ft1 CFM/sq ft @ 99 CFM
Tall Bath (9-ft Ceiling)Up to 88 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 49 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.4 kWh/yr (~$1.34/yr)22.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2200.6 kWh/yr (~$32.10/yr)22.9 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against BV BV-BF-02-PLUS?

Compare BV BV-BF-02-PLUS side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Valu+ BPT14-24TGHS 110 / 99 CFM 1.2 sones (Same) 4.8 CFM/W 4 in. diameter
Nektra 3291028 110 / 98.7 CFM 1.2 sones (Same) 4.5 CFM/W 4 in. diameter
Win Air BPT14-24E 110 / 98.7 CFM 1.2 sones (Same) 4.5 CFM/W 4 in. diameter
COSTWAY BPT14-24A-A-1 110 / 97.5 CFM 1.2 sones (Same) 4.3 CFM/W 4 in. diameter
Loren Cook Company GC-222 115 / 85 CFM 1.2 sones (Same) 4.8 CFM/W 4.5 x 6 in. rectangular

Can you size BV BV-BF-02-PLUS for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against BV BV-BF-02-PLUS verified capacity.

When does BV BV-BF-02-PLUS fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering BV BV-BF-02-PLUS.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 99 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around 1.2 sones up to 99 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to BV BV-BF-02-PLUS?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for BV BV-BF-02-PLUS.

How much airflow does BV BV-BF-02-PLUS retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, BV BV-BF-02-PLUS produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will BV BV-BF-02-PLUS disturb adjacent bedrooms during night use?

Acoustic measurement places BV BV-BF-02-PLUS at 1.2 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running BV BV-BF-02-PLUS continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of BV BV-BF-02-PLUS draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can BV BV-BF-02-PLUS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from BV BV-BF-02-PLUS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing BV BV-BF-02-PLUS?

BV BV-BF-02-PLUS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change BV BV-BF-02-PLUS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing BV BV-BF-02-PLUS's safe coverage footprint from 50 sq ft to 44 sq ft.

Is BV BV-BF-02-PLUS code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), BV BV-BF-02-PLUS clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than BV BV-BF-02-PLUS?

Do not force BV BV-BF-02-PLUS into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.