In EPA dataset 8dv7-nngq, Valu+ BPT14-24TGHS tests at 110 CFM free discharge (99 CFM at 0.25 in. w.g.) and registers #380 of 607 in quietness (1.2 sones) and delivers 4.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 99 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Valu+ BPT14-24TGHS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 99 CFM
- Noise @ 0.1"
- 1.2 sones (#380/607)
- Efficacy Rank
- 4.8 CFM/W (#534/1,145)
- Static Retention
- 90.0% @ 0.25"
- Motor Draw
- 22.9 W (8.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Valu+ BPT14-24TGHS vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 110 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Valu+ registers 2 certified models, with SKU BPT14-24TGHS (series: 1) (PD #3999573) certified since 2025-03-07. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include BV BV-BF-02-PLUS (110.0 CFM) and Nektra 3291028 (110.0 CFM).
Does Valu+ BPT14-24TGHS fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Valu+ BPT14-24TGHS at 1.2 sones.
Why avoid unvented attic termination with Valu+ BPT14-24TGHS?
Under ASHRAE 62.2 best practice, Valu+ BPT14-24TGHS needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Valu+ BPT14-24TGHS?
Before cutting ceiling drywall or sizing attic transitions for Valu+ BPT14-24TGHS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Valu+ (2 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT14-24TGHS / 1 | PD ID 3999573 (Qualified 2025-03-07) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (99 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Valu+ BPT14-24TGHS?
Bathroom ventilation sizing below maps Valu+ BPT14-24TGHS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 99 sq ft | 1 CFM/sq ft @ 99 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 49 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |
What peer models sit nearest Valu+ BPT14-24TGHS in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Valu+ BPT14-24TGHS.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| BV BV-BF-02-PLUS | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Nektra 3291028 | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Win Air BPT14-24E | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| COSTWAY BPT14-24A-A-1 | 110 / 97.5 CFM | 1.2 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| Loren Cook Company GC-222 | 115 / 85 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4.5 x 6 in. rectangular |
What percentage of room demand does Valu+ BPT14-24TGHS cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Valu+ BPT14-24TGHS tested delivery.
Who should not install Valu+ BPT14-24TGHS in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Valu+ BPT14-24TGHS for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 99 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 1.2 sones up to 99 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Valu+ BPT14-24TGHS?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Valu+ BPT14-24TGHS.
Does Valu+ BPT14-24TGHS satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Valu+ BPT14-24TGHS clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Valu+ BPT14-24TGHS undersized or poorly matched for a bath renovation?
Skip Valu+ BPT14-24TGHS if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Valu+ BPT14-24TGHS CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Valu+ BPT14-24TGHS registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Valu+ BPT14-24TGHS sound output compare to noisy contractor-grade fans?
Rated at 1.2 sones, Valu+ BPT14-24TGHS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Valu+ BPT14-24TGHS?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Valu+ BPT14-24TGHS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Valu+ BPT14-24TGHS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Valu+ BPT14-24TGHS?
Valu+ BPT14-24TGHS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Valu+ BPT14-24TGHS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Valu+ BPT14-24TGHS's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)