Skip to main content
Grant Estimator

Valu+ BPT14-24TGHS Exhaust Fan Specifications

ENERGY STAR PD #3999573 · Bathroom/Utility Room · Qualified 2025-03-07
Verified Specification Summary

In EPA dataset 8dv7-nngq, Valu+ BPT14-24TGHS tests at 110 CFM free discharge (99 CFM at 0.25 in. w.g.) and registers #380 of 607 in quietness (1.2 sones) and delivers 4.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 99 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Valu+ BPT14-24TGHS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 99 CFM
Noise @ 0.1"
1.2 sones (#380/607)
Efficacy Rank
4.8 CFM/W (#534/1,145)
Static Retention
90.0% @ 0.25"
Motor Draw
22.9 W (8.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Valu+ BPT14-24TGHS vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 110 CFM (90.0% retention, 2.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Valu+ registers 2 certified models, with SKU BPT14-24TGHS (series: 1) (PD #3999573) certified since 2025-03-07. Lighting kit: No. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include BV BV-BF-02-PLUS (110.0 CFM) and Nektra 3291028 (110.0 CFM).

Does Valu+ BPT14-24TGHS fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Valu+ BPT14-24TGHS at 1.2 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.2 sone: 1.2 sones (65th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.2 sone: 1.2 sones (P65)

Why avoid unvented attic termination with Valu+ BPT14-24TGHS?

Under ASHRAE 62.2 best practice, Valu+ BPT14-24TGHS needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Valu+ BPT14-24TGHS?

Before cutting ceiling drywall or sizing attic transitions for Valu+ BPT14-24TGHS, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Valu+ (2 models) ENERGY STAR Certified Partner
Model Number & Series BPT14-24TGHS / 1 PD ID 3999573 (Qualified 2025-03-07)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (99 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.2 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Valu+ BPT14-24TGHS?

Bathroom ventilation sizing below maps Valu+ BPT14-24TGHS motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Valu+ BPT14-24TGHS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 99 sq ft1 CFM/sq ft @ 99 CFM
Tall Bath (9-ft Ceiling)Up to 88 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 49 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.4 kWh/yr (~$1.34/yr)22.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2200.6 kWh/yr (~$32.10/yr)22.9 W x 8,760 hrs / 1,000

What peer models sit nearest Valu+ BPT14-24TGHS in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Valu+ BPT14-24TGHS.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
BV BV-BF-02-PLUS 110 / 99 CFM 1.2 sones (Same) 4.8 CFM/W 4 in. diameter
Nektra 3291028 110 / 98.7 CFM 1.2 sones (Same) 4.5 CFM/W 4 in. diameter
Win Air BPT14-24E 110 / 98.7 CFM 1.2 sones (Same) 4.5 CFM/W 4 in. diameter
COSTWAY BPT14-24A-A-1 110 / 97.5 CFM 1.2 sones (Same) 4.3 CFM/W 4 in. diameter
Loren Cook Company GC-222 115 / 85 CFM 1.2 sones (Same) 4.8 CFM/W 4.5 x 6 in. rectangular

What percentage of room demand does Valu+ BPT14-24TGHS cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Valu+ BPT14-24TGHS tested delivery.

Who should not install Valu+ BPT14-24TGHS in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Valu+ BPT14-24TGHS for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 99 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 1.2 sones up to 99 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Valu+ BPT14-24TGHS?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Valu+ BPT14-24TGHS.

Does Valu+ BPT14-24TGHS satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Valu+ BPT14-24TGHS clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Valu+ BPT14-24TGHS undersized or poorly matched for a bath renovation?

Skip Valu+ BPT14-24TGHS if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Valu+ BPT14-24TGHS CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Valu+ BPT14-24TGHS registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Valu+ BPT14-24TGHS sound output compare to noisy contractor-grade fans?

Rated at 1.2 sones, Valu+ BPT14-24TGHS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Valu+ BPT14-24TGHS?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Valu+ BPT14-24TGHS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Valu+ BPT14-24TGHS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Valu+ BPT14-24TGHS?

Valu+ BPT14-24TGHS features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Valu+ BPT14-24TGHS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Valu+ BPT14-24TGHS's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories