In EPA dataset 8dv7-nngq, Nektra 3291028 tests at 110 CFM free discharge (98.7 CFM at 0.25 in. w.g.) and registers #380 of 607 in quietness (1.2 sones) and delivers 4.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 98 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nektra 3291028 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 98.7 CFM
- Noise @ 0.1"
- 1.2 sones (#380/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 89.7% @ 0.25"
- Motor Draw
- 24.4 W (8.9 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Nektra 3291028 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 98.7 CFM out of 110 CFM (89.7% retention, 2.0 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Nektra's 4-unit lineup, 3291028 (series: 329) carries PD #3057294 dating to 2023-11-17. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Win Air BPT14-24E (110.0 CFM) and COSTWAY BPT14-24A-A-1 (110.0 CFM).
Does Nektra 3291028 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Nektra 3291028 at 1.2 sones.
Why avoid unvented attic termination with Nektra 3291028?
Under ASHRAE 62.2 best practice, Nektra 3291028 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Nektra 3291028?
Before cutting ceiling drywall or sizing attic transitions for Nektra 3291028, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Nektra (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 3291028 / 329 | PD ID 3057294 (Qualified 2023-11-17) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (98.7 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Nektra 3291028?
Bathroom ventilation sizing below maps Nektra 3291028 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 98 sq ft | 1 CFM/sq ft @ 98.7 CFM |
| Tall Bath (9-ft Ceiling) | Up to 87 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 48 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.9 kWh/yr (~$1.42/yr) | 24.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 213.7 kWh/yr (~$34.19/yr) | 24.4 W x 8,760 hrs / 1,000 |
What peer models sit nearest Nektra 3291028 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Nektra 3291028.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Win Air BPT14-24E | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| COSTWAY BPT14-24A-A-1 | 110 / 97.5 CFM | 1.2 sones (Same) | 4.3 CFM/W | 4 in. diameter |
| BV BV-BF-02-PLUS | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Valu+ BPT14-24TGHS | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Loren Cook Company GC-222 | 115 / 85 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4.5 x 6 in. rectangular |
What percentage of room demand does Nektra 3291028 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Nektra 3291028 tested delivery.
When does Nektra 3291028 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Nektra 3291028.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 98.7 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around 1.2 sones up to 98 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Nektra 3291028?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Nektra 3291028.
Does running Nektra 3291028 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Nektra 3291028 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Nektra 3291028 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nektra 3291028's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Nektra 3291028?
Nektra 3291028 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Nektra 3291028's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nektra 3291028's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Nektra 3291028 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Nektra 3291028 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Nektra 3291028?
Do not force Nektra 3291028 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Nektra 3291028 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Nektra 3291028 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Nektra 3291028 disturb adjacent bedrooms during night use?
Acoustic measurement places Nektra 3291028 at 1.2 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.