Skip to main content
Grant Estimator

Win Air BPT14-24E Exhaust Fan Specifications

ENERGY STAR PD #2376701 · Bathroom/Utility Room · Qualified 2021-04-16
Verified Specification Summary

Rated for 110 CFM open-air (98.7 CFM at 0.25 in. w.g.), Win Air BPT14-24E registers #380 of 607 in quietness (1.2 sones) and delivers 4.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 98 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Win Air BPT14-24E Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 98.7 CFM
Noise @ 0.1"
1.2 sones (#380/607)
Efficacy Rank
4.5 CFM/W (#632/1,145)
Static Retention
89.7% @ 0.25"
Motor Draw
24.4 W (8.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Win Air BPT14-24E vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 98.7 CFM out of 110 CFM (89.7% retention, 2.0 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2376701 verifies BPT14-24E (series: BPT) under Win Air (3 listed models, qualified 2021-04-16). Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.4 watts, about 8.9 kWh/yr (~$1.42/yr at $0.16/kWh) for 1 hr/day shower timers or 213.7 kWh/yr (~$34.19/yr) continuously. Closest competing matches include Nektra 3291028 (110.0 CFM) and COSTWAY BPT14-24A-A-1 (110.0 CFM).

How does Win Air BPT14-24E acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Win Air BPT14-24E (1.2 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.2 sone: 1.2 sones (65th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.2 sone: 1.2 sones (P65)

How do flex elbows choke Win Air BPT14-24E at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Win Air BPT14-24E moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Win Air BPT14-24E meet residential exhaust fan code specs?

Inspect Win Air BPT14-24E mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Win Air (3 models) ENERGY STAR Certified Partner
Model Number & Series BPT14-24E / BPT PD ID 2376701 (Qualified 2021-04-16)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (98.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.2 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Win Air BPT14-24E airflow output?

Annual electricity figures and room square-footage ceilings below reflect Win Air BPT14-24E tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Win Air BPT14-24E
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 98 sq ft1 CFM/sq ft @ 98.7 CFM
Tall Bath (9-ft Ceiling)Up to 87 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 48 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.9 kWh/yr (~$1.42/yr)24.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2213.7 kWh/yr (~$34.19/yr)24.4 W x 8,760 hrs / 1,000

Which competing models share Win Air BPT14-24E airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Nektra 3291028 110 / 98.7 CFM 1.2 sones (Same) 4.5 CFM/W 4 in. diameter
COSTWAY BPT14-24A-A-1 110 / 97.5 CFM 1.2 sones (Same) 4.3 CFM/W 4 in. diameter
BV BV-BF-02-PLUS 110 / 99 CFM 1.2 sones (Same) 4.8 CFM/W 4 in. diameter
Valu+ BPT14-24TGHS 110 / 99 CFM 1.2 sones (Same) 4.8 CFM/W 4 in. diameter
Loren Cook Company GC-222 115 / 85 CFM 1.2 sones (Same) 4.8 CFM/W 4.5 x 6 in. rectangular

How much airflow margin does Win Air BPT14-24E give your bath?

Run a quick local room-volume check for Win Air BPT14-24E by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Win Air BPT14-24E on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Win Air BPT14-24E carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 48 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 98 sq ft with 8-ft ceilings (87 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Win Air BPT14-24E?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Win Air BPT14-24E.

What duct and room conditions disqualify Win Air BPT14-24E?

Rule out Win Air BPT14-24E when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Win Air BPT14-24E capacity?

Because static drag at 0.25 in. w.g. lowers Win Air BPT14-24E from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Win Air BPT14-24E compared with a standard 3.0 sone builder fan?

Tested at 1.2 sones, Win Air BPT14-24E produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Win Air BPT14-24E consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Win Air BPT14-24E draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Win Air BPT14-24E pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Win Air BPT14-24E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Win Air BPT14-24E?

Win Air BPT14-24E features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Win Air BPT14-24E's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Win Air BPT14-24E's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Win Air BPT14-24E score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Win Air BPT14-24E delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories