Tested under HVI protocols, the COSTWAY BPT14-24A-A-1 exhaust unit achieves 110 CFM at 0.1 in. w.g. (97.5 CFM at 0.25 in. w.g.), registers #380 of 607 in quietness (1.2 sones) and delivers 4.3 CFM/W efficacy, covering standard baths up to 97 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside COSTWAY BPT14-24A-A-1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 97.5 CFM
- Noise @ 0.1"
- 1.2 sones (#380/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 88.6% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does COSTWAY BPT14-24A-A-1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97.5 CFM out of 110 CFM (88.6% retention, 0.9 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: COSTWAY registers 2 certified models, with SKU BPT14-24A-A-1 (series: BPT14-24A-A-1) (PD #3892185) certified since 2024-12-20. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Nektra 3291028 (110.0 CFM) and Win Air BPT14-24E (110.0 CFM).
Where do COSTWAY BPT14-24A-A-1 sones rank across EPA ENERGY STAR fans?
Comparing COSTWAY BPT14-24A-A-1 (1.2 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves COSTWAY BPT14-24A-A-1 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on COSTWAY BPT14-24A-A-1, preventing premature peeling paint and mold growth.
How does COSTWAY BPT14-24A-A-1 measure up on airflow and noise ratings?
Each row below breaks down COSTWAY BPT14-24A-A-1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | COSTWAY (2 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT14-24A-A-1 / BPT14-24A-A-1 | PD ID 3892185 (Qualified 2024-12-20) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (97.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect COSTWAY BPT14-24A-A-1 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 97 sq ft | 1 CFM/sq ft @ 97.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 86 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 47 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against COSTWAY BPT14-24A-A-1?
Compare COSTWAY BPT14-24A-A-1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nektra 3291028 | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Win Air BPT14-24E | 110 / 98.7 CFM | 1.2 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| BV BV-BF-02-PLUS | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Valu+ BPT14-24TGHS | 110 / 99 CFM | 1.2 sones (Same) | 4.8 CFM/W | 4 in. diameter |
| Anzzi EF-AZ102WH | 110 / 101.4 CFM | 1.3 sones (+0.10) | 4.3 CFM/W | 4 in. diameter |
Can you size COSTWAY BPT14-24A-A-1 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against COSTWAY BPT14-24A-A-1 verified capacity.
What plumbing or duct constraints rule out COSTWAY BPT14-24A-A-1?
Compare where COSTWAY BPT14-24A-A-1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 97.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 1.2 sones up to 97 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to COSTWAY BPT14-24A-A-1?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for COSTWAY BPT14-24A-A-1.
Why might a contractor swap COSTWAY BPT14-24A-A-1 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, COSTWAY BPT14-24A-A-1 lacks adequate reserve.
How does COSTWAY BPT14-24A-A-1 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., COSTWAY BPT14-24A-A-1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is COSTWAY BPT14-24A-A-1 quiet enough for a primary bedroom bathroom?
At 1.2 sones, COSTWAY BPT14-24A-A-1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is COSTWAY BPT14-24A-A-1 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can COSTWAY BPT14-24A-A-1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from COSTWAY BPT14-24A-A-1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing COSTWAY BPT14-24A-A-1?
COSTWAY BPT14-24A-A-1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change COSTWAY BPT14-24A-A-1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing COSTWAY BPT14-24A-A-1's safe coverage footprint from 50 sq ft to 44 sq ft.
Can COSTWAY BPT14-24A-A-1 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: COSTWAY BPT14-24A-A-1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.