Skip to main content
Grant Estimator

HomeWerks Worldwide 7130-40-BT Exhaust Fan Specifications

ENERGY STAR PD #3553969 · Bathroom/Utility Room · Qualified 2024-07-05
Verified Specification Summary

Tested under HVI protocols, the HomeWerks Worldwide 7130-40-BT exhaust unit achieves 90 CFM at 0.1 in. w.g. (84.3 CFM at 0.25 in. w.g.), registers #380 of 607 in quietness (1.2 sones) and delivers 7.7 CFM/W efficacy, covering standard baths up to 84 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7130-40-BT Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
90 / 84.3 CFM
Noise @ 0.1"
1.2 sones (#380/607)
Efficacy Rank
7.7 CFM/W (#377/1,145)
Static Retention
93.7% @ 0.25"
Motor Draw
11.7 W (4.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does HomeWerks Worldwide 7130-40-BT vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 84.3 CFM out of 90 CFM (93.7% retention, 6.0 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 7130-40-BT (series: 7130-40-BT) (PD #3553969) among 31 HomeWerks Worldwide entries qualified through 2024-07-05. Lighting kit: Yes. At 7.7 CFM/W (#377 of 1,145, top 33.1% of 1,145 rated models, more efficient than 66.9% of rated models, 3.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.7 watts, about 4.3 kWh/yr (~$0.69/yr at $0.16/kWh) for 1 hr/day shower timers or 102.5 kWh/yr (~$16.40/yr) continuously. Closest competing matches include Panasonic RG-S100A (100.0 CFM) and Delta ITG80LED (80.0 CFM).

Where do HomeWerks Worldwide 7130-40-BT sones rank across EPA ENERGY STAR fans?

Comparing HomeWerks Worldwide 7130-40-BT (1.2 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.2 sone: 1.2 sones (65th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.2 sone: 1.2 sones (P65)

What attic duct routing preserves HomeWerks Worldwide 7130-40-BT CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on HomeWerks Worldwide 7130-40-BT, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does HomeWerks Worldwide 7130-40-BT measure up on airflow and noise ratings?

Each row below breaks down HomeWerks Worldwide 7130-40-BT certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share HomeWerks Worldwide (31 models) ENERGY STAR Certified Partner
Model Number & Series 7130-40-BT / 7130-40-BT PD ID 3553969 (Qualified 2024-07-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (84.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.2 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect HomeWerks Worldwide 7130-40-BT CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for HomeWerks Worldwide 7130-40-BT
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 84 sq ft1 CFM/sq ft @ 84.3 CFM
Tall Bath (9-ft Ceiling)Up to 74 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 34 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.3 kWh/yr (~$0.69/yr)11.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2102.5 kWh/yr (~$16.40/yr)11.7 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against HomeWerks Worldwide 7130-40-BT?

Compare HomeWerks Worldwide 7130-40-BT side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic RG-S100A 100 / 100.1 CFM 1.1 sones (-0.10) 7.6 CFM/W 4 in. diameter
Delta ITG80LED 80 / 61.5 CFM 1.3 sones (+0.10) 7.2 CFM/W 4 in. diameter
Delta ITG80 80 / 68.3 CFM 1.3 sones (+0.10) 8.4 CFM/W 4 in. diameter
Delta 100F 100 / 81.4 CFM 1.4 sones (+0.20) 7.9 CFM/W 4 in. diameter
Delta GBR100 100 / 81.4 CFM 1.4 sones (+0.20) 7.9 CFM/W 4 in. diameter

Can you size HomeWerks Worldwide 7130-40-BT for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against HomeWerks Worldwide 7130-40-BT verified capacity.

Does HomeWerks Worldwide 7130-40-BT suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying HomeWerks Worldwide 7130-40-BT for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 84.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 1.2 sones up to 84 sq ft
  • Best application: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to HomeWerks Worldwide 7130-40-BT?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for HomeWerks Worldwide 7130-40-BT.

Who should NOT install HomeWerks Worldwide 7130-40-BT in a bathroom remodel?

Avoid specifying HomeWerks Worldwide 7130-40-BT in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut HomeWerks Worldwide 7130-40-BT airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, HomeWerks Worldwide 7130-40-BT achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does HomeWerks Worldwide 7130-40-BT occupy in EPA filings?

With 1.2 sones at 0.1 in. w.g., HomeWerks Worldwide 7130-40-BT produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does HomeWerks Worldwide 7130-40-BT add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, HomeWerks Worldwide 7130-40-BT averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can HomeWerks Worldwide 7130-40-BT pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7130-40-BT's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing HomeWerks Worldwide 7130-40-BT?

HomeWerks Worldwide 7130-40-BT features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change HomeWerks Worldwide 7130-40-BT's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7130-40-BT's safe coverage footprint from 50 sq ft to 44 sq ft.

Does HomeWerks Worldwide 7130-40-BT pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7130-40-BT easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories