Tested under HVI protocols, the HomeWerks Worldwide 7130-40-BT exhaust unit achieves 90 CFM at 0.1 in. w.g. (84.3 CFM at 0.25 in. w.g.), registers #380 of 607 in quietness (1.2 sones) and delivers 7.7 CFM/W efficacy, covering standard baths up to 84 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7130-40-BT Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 84.3 CFM
- Noise @ 0.1"
- 1.2 sones (#380/607)
- Efficacy Rank
- 7.7 CFM/W (#377/1,145)
- Static Retention
- 93.7% @ 0.25"
- Motor Draw
- 11.7 W (4.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does HomeWerks Worldwide 7130-40-BT vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 84.3 CFM out of 90 CFM (93.7% retention, 6.0 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places 7130-40-BT (series: 7130-40-BT) (PD #3553969) among 31 HomeWerks Worldwide entries qualified through 2024-07-05. Lighting kit: Yes. At 7.7 CFM/W (#377 of 1,145, top 33.1% of 1,145 rated models, more efficient than 66.9% of rated models, 3.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.7 watts, about 4.3 kWh/yr (~$0.69/yr at $0.16/kWh) for 1 hr/day shower timers or 102.5 kWh/yr (~$16.40/yr) continuously. Closest competing matches include Panasonic RG-S100A (100.0 CFM) and Delta ITG80LED (80.0 CFM).
Where do HomeWerks Worldwide 7130-40-BT sones rank across EPA ENERGY STAR fans?
Comparing HomeWerks Worldwide 7130-40-BT (1.2 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves HomeWerks Worldwide 7130-40-BT CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on HomeWerks Worldwide 7130-40-BT, preventing premature peeling paint and mold growth.
How does HomeWerks Worldwide 7130-40-BT measure up on airflow and noise ratings?
Each row below breaks down HomeWerks Worldwide 7130-40-BT certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7130-40-BT / 7130-40-BT | PD ID 3553969 (Qualified 2024-07-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (84.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect HomeWerks Worldwide 7130-40-BT CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 74 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.3 kWh/yr (~$0.69/yr) | 11.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 102.5 kWh/yr (~$16.40/yr) | 11.7 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against HomeWerks Worldwide 7130-40-BT?
Compare HomeWerks Worldwide 7130-40-BT side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic RG-S100A | 100 / 100.1 CFM | 1.1 sones (-0.10) | 7.6 CFM/W | 4 in. diameter |
| Delta ITG80LED | 80 / 61.5 CFM | 1.3 sones (+0.10) | 7.2 CFM/W | 4 in. diameter |
| Delta ITG80 | 80 / 68.3 CFM | 1.3 sones (+0.10) | 8.4 CFM/W | 4 in. diameter |
| Delta 100F | 100 / 81.4 CFM | 1.4 sones (+0.20) | 7.9 CFM/W | 4 in. diameter |
| Delta GBR100 | 100 / 81.4 CFM | 1.4 sones (+0.20) | 7.9 CFM/W | 4 in. diameter |
Can you size HomeWerks Worldwide 7130-40-BT for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against HomeWerks Worldwide 7130-40-BT verified capacity.
Does HomeWerks Worldwide 7130-40-BT suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying HomeWerks Worldwide 7130-40-BT for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 84.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 1.2 sones up to 84 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to HomeWerks Worldwide 7130-40-BT?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for HomeWerks Worldwide 7130-40-BT.
Who should NOT install HomeWerks Worldwide 7130-40-BT in a bathroom remodel?
Avoid specifying HomeWerks Worldwide 7130-40-BT in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut HomeWerks Worldwide 7130-40-BT airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, HomeWerks Worldwide 7130-40-BT achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does HomeWerks Worldwide 7130-40-BT occupy in EPA filings?
With 1.2 sones at 0.1 in. w.g., HomeWerks Worldwide 7130-40-BT produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does HomeWerks Worldwide 7130-40-BT add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, HomeWerks Worldwide 7130-40-BT averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can HomeWerks Worldwide 7130-40-BT pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7130-40-BT's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing HomeWerks Worldwide 7130-40-BT?
HomeWerks Worldwide 7130-40-BT features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change HomeWerks Worldwide 7130-40-BT's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7130-40-BT's safe coverage footprint from 50 sq ft to 44 sq ft.
Does HomeWerks Worldwide 7130-40-BT pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7130-40-BT easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)