Skip to main content
Grant Estimator

Fantech RCS80L Exhaust Fan Specifications

ENERGY STAR PD #3555661 · Bathroom/Utility Room · Qualified 2024-07-19
Verified Specification Summary

In EPA dataset 8dv7-nngq, Fantech RCS80L tests at 80 CFM free discharge (80.4 CFM at 0.25 in. w.g.) and registers #380 of 607 in quietness (1.2 sones) and delivers 5.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 80 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech RCS80L Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 80.4 CFM
Noise @ 0.1"
1.2 sones (#380/607)
Efficacy Rank
5.1 CFM/W (#507/1,145)
Static Retention
100.5% @ 0.25"
Motor Draw
15.7 W (5.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech RCS80L vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 80.4 CFM out of 80 CFM (100.5% retention, 12.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3555661 verifies RCS80L (series: RCS) under Fantech (52 listed models, qualified 2024-07-19). Lighting kit: Yes. At 5.1 CFM/W (#507 of 1,145, top 44.8% of 1,145 rated models, more efficient than 55.2% of rated models, 0.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.7 watts, about 5.7 kWh/yr (~$0.91/yr at $0.16/kWh) for 1 hr/day shower timers or 137.5 kWh/yr (~$22.00/yr) continuously. Closest competing matches include S&P PCLP80 (80.0 CFM) and HomeWerks Worldwide 7117-01-BN (80.0 CFM).

Does Fantech RCS80L fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Fantech RCS80L at 1.2 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.2 sone: 1.2 sones (65th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.2 sone: 1.2 sones (P65)

Why avoid unvented attic termination with Fantech RCS80L?

Under ASHRAE 62.2 best practice, Fantech RCS80L needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Fantech RCS80L?

Before cutting ceiling drywall or sizing attic transitions for Fantech RCS80L, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series RCS80L / RCS PD ID 3555661 (Qualified 2024-07-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (80.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.2 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Fantech RCS80L?

Bathroom ventilation sizing below maps Fantech RCS80L motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Fantech RCS80L
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 80 sq ft1 CFM/sq ft @ 80.4 CFM
Tall Bath (9-ft Ceiling)Up to 71 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 30 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.7 kWh/yr (~$0.91/yr)15.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2137.5 kWh/yr (~$22.00/yr)15.7 W x 8,760 hrs / 1,000

What peer models sit nearest Fantech RCS80L in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Fantech RCS80L.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
S&P PCLP80 80 / 68.3 CFM 1.2 sones (Same) 4.7 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-01-BN 80 / 65.4 CFM 1.1 sones (-0.10) 4.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-01-WH 80 / 65.4 CFM 1.1 sones (-0.10) 4.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80 80 / 62.9 CFM 1.1 sones (-0.10) 4.1 CFM/W 4 in. diameter
Air King LEDAK80 80 / 70.3 CFM 1.2 sones (Same) 3.5 CFM/W 4 in. diameter

What percentage of room demand does Fantech RCS80L cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Fantech RCS80L tested delivery.

Which bath layouts should avoid specifying Fantech RCS80L?

Match Fantech RCS80L directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 80.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around 1.2 sones up to 80 sq ft
  • Optimal use: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Fantech RCS80L?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantech RCS80L.

Where does Fantech RCS80L run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Fantech RCS80L.

What happens to Fantech RCS80L CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Fantech RCS80L moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Fantech RCS80L sit on acoustic comfort for senior homeowners?

Measuring 1.2 sones, Fantech RCS80L produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Fantech RCS80L cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Fantech RCS80L 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Fantech RCS80L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech RCS80L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech RCS80L?

Fantech RCS80L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech RCS80L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech RCS80L's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Fantech RCS80L ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Fantech RCS80L covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories