Skip to main content
Grant Estimator

S&P PCLP80 Exhaust Fan Specifications

ENERGY STAR PD #2382099 · Bathroom/Utility Room · Qualified 2021-06-25
Verified Specification Summary

Homeowners specifying S&P PCLP80 gain 80 CFM at 0.1 in. w.g. (68.3 CFM at 0.25 in. w.g.) where it registers #380 of 607 in quietness (1.2 sones) and delivers 4.7 CFM/W efficacy, venting bathrooms up to 68 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCLP80 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 68.3 CFM
Noise @ 0.1"
1.2 sones (#380/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
85.4% @ 0.25"
Motor Draw
17.0 W (6.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P PCLP80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.3 CFM out of 80 CFM (85.4% retention, 2.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms S&P PCLP80 (series: PCLP) under PD #2382099 (29 models registered, 2021-06-25). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include Fantech RCS80L (80.0 CFM) and HomeWerks Worldwide 7117-01-BN (80.0 CFM).

What acoustic percentile does S&P PCLP80 occupy among 1,145 bath blowers?

Inspect how S&P PCLP80 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.2 sone: 1.2 sones (65th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.2 sone: 1.2 sones (P65)

Which exterior damper path suits S&P PCLP80 best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around S&P PCLP80 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do S&P PCLP80 acoustic and static metrics stand?

Compare S&P PCLP80 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series PCLP80 / PCLP PD ID 2382099 (Qualified 2021-06-25)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (68.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.2 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can S&P PCLP80 handle taller ceilings or walk-in tub steam?

Evaluate how S&P PCLP80 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for S&P PCLP80
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 68 sq ft1 CFM/sq ft @ 68.3 CFM
Tall Bath (9-ft Ceiling)Up to 60 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.2 kWh/yr (~$0.99/yr)17.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2148.9 kWh/yr (~$23.82/yr)17.0 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near S&P PCLP80?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Fantech RCS80L 80 / 80.4 CFM 1.2 sones (Same) 5.1 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-01-BN 80 / 65.4 CFM 1.1 sones (-0.10) 4.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-01-WH 80 / 65.4 CFM 1.1 sones (-0.10) 4.6 CFM/W 4 in. diameter
Fantech SMPL80 (484300) 80 / 75 CFM 1.1 sones (-0.10) 5.0 CFM/W 4 in. diameter
Fantech SMPL80L (484301) 80 / 75 CFM 1.1 sones (-0.10) 5.0 CFM/W 4 in. diameter

Is S&P PCLP80 sized right for your shower or tub room?

Check whether S&P PCLP80 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Which bath layouts should avoid specifying S&P PCLP80?

Match S&P PCLP80 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 68.3 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for S&P PCLP80?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to S&P PCLP80.

Where does S&P PCLP80 sit on acoustic comfort for senior homeowners?

Measuring 1.2 sones, S&P PCLP80 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does S&P PCLP80 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running S&P PCLP80 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can S&P PCLP80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCLP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P PCLP80?

S&P PCLP80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P PCLP80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCLP80's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can S&P PCLP80 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), S&P PCLP80 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does S&P PCLP80 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with S&P PCLP80.

What happens to S&P PCLP80 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, S&P PCLP80 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories