Rated for 80 CFM open-air (75 CFM at 0.25 in. w.g.), Fantech SMPL80 (484300) registers #357 of 607 in quietness (1.1 sones) and delivers 5.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 75 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SMPL80 (484300) Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 75 CFM
- Noise @ 0.1"
- 1.1 sones (#357/607)
- Efficacy Rank
- 5.0 CFM/W (#514/1,145)
- Static Retention
- 93.8% @ 0.25"
- Motor Draw
- 16.0 W (5.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Fantech SMPL80 (484300) vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 75 CFM out of 80 CFM (93.8% retention, 6.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Fantech SMPL80 (484300) (series: bathfan Simple) under PD #2507833 (52 models registered, 2023-05-19). Lighting kit: No. At 5.0 CFM/W (#514 of 1,145, top 45.2% of 1,145 rated models, more efficient than 54.8% of rated models, 0.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.0 watts, about 5.8 kWh/yr (~$0.93/yr at $0.16/kWh) for 1 hr/day shower timers or 140.2 kWh/yr (~$22.43/yr) continuously. Closest competing matches include HomeWerks Worldwide 7117-01-BN (80.0 CFM) and HomeWerks Worldwide 7117-01-WH (80.0 CFM).
How does Fantech SMPL80 (484300) acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Fantech SMPL80 (484300) (1.1 sones).
How do flex elbows choke Fantech SMPL80 (484300) at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Fantech SMPL80 (484300) moving full rated CFM.
Does Fantech SMPL80 (484300) meet residential exhaust fan code specs?
Inspect Fantech SMPL80 (484300) mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SMPL80 (484300) / bathfan Simple | PD ID 2507833 (Qualified 2023-05-19) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (75 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.1 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Fantech SMPL80 (484300) airflow output?
Annual electricity figures and room square-footage ceilings below reflect Fantech SMPL80 (484300) tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 75 sq ft | 1 CFM/sq ft @ 75 CFM |
| Tall Bath (9-ft Ceiling) | Up to 66 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 25 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.8 kWh/yr (~$0.93/yr) | 16.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 140.2 kWh/yr (~$22.43/yr) | 16.0 W x 8,760 hrs / 1,000 |
Which competing models share Fantech SMPL80 (484300) airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| HomeWerks Worldwide 7117-01-BN | 80 / 65.4 CFM | 1.1 sones (Same) | 4.6 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7117-01-WH | 80 / 65.4 CFM | 1.1 sones (Same) | 4.6 CFM/W | 4 in. diameter |
| S&P PCLP80 | 80 / 68.3 CFM | 1.2 sones (+0.10) | 4.7 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7141-80 | 80 / 62.9 CFM | 1.1 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Panasonic FV-08VRE2 | 80 / 66.7 CFM | 1.0 sones (-0.10) | 4.3 CFM/W | 4 in. diameter |
How much airflow margin does Fantech SMPL80 (484300) give your bath?
Run a quick local room-volume check for Fantech SMPL80 (484300) by entering square footage and ceiling height to spot under-vented steam risks early.
When does Fantech SMPL80 (484300) fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Fantech SMPL80 (484300).
Limitations & Who Should Skip
- Steam or walk-in tub room > 25 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 75 sq ft with 8-ft ceilings (66 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Fantech SMPL80 (484300)?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Fantech SMPL80 (484300).
Is Fantech SMPL80 (484300) code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Fantech SMPL80 (484300) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Fantech SMPL80 (484300)?
Do not force Fantech SMPL80 (484300) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Fantech SMPL80 (484300) retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Fantech SMPL80 (484300) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Fantech SMPL80 (484300) disturb adjacent bedrooms during night use?
Acoustic measurement places Fantech SMPL80 (484300) at 1.1 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Fantech SMPL80 (484300) continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Fantech SMPL80 (484300) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Fantech SMPL80 (484300) pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SMPL80 (484300)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech SMPL80 (484300)?
Fantech SMPL80 (484300) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech SMPL80 (484300)'s room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SMPL80 (484300)'s safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)