Homeowners specifying Commercial Electric 7132-12-CE gain 80 CFM at 0.1 in. w.g. (57.1 CFM at 0.25 in. w.g.) where it registers #357 of 607 in quietness (1.1 sones) and delivers 3.3 CFM/W efficacy, venting bathrooms up to 57 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric 7132-12-CE Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 57.1 CFM
- Noise @ 0.1"
- 1.1 sones (#357/607)
- Efficacy Rank
- 3.3 CFM/W (#1,077/1,145)
- Static Retention
- 71.4% @ 0.25"
- Motor Draw
- 24.2 W (8.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Commercial Electric 7132-12-CE vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 57.1 CFM at 0.25 in. w.g. (71.4% retention, 16.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Commercial Electric registers 15 certified models, with SKU 7132-12-CE (series: 7132-12-CE) (PD #3477949) certified since 2024-05-03. Lighting kit: Yes. At 3.3 CFM/W (#1,077 of 1,145, below median tier among 1,145 rated models; more efficient than 4.8% of rated models, 1.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.2 watts, about 8.8 kWh/yr (~$1.41/yr at $0.16/kWh) for 1 hr/day shower timers or 212.0 kWh/yr (~$33.92/yr) continuously. Closest competing matches include Utilitech 7105-08-L (80.0 CFM) and Broan (Canada) EZ80C (80.0 CFM).
What acoustic percentile does Commercial Electric 7132-12-CE occupy among 1,145 bath blowers?
Inspect how Commercial Electric 7132-12-CE positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Commercial Electric 7132-12-CE best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Commercial Electric 7132-12-CE housings.
Where do Commercial Electric 7132-12-CE acoustic and static metrics stand?
Compare Commercial Electric 7132-12-CE published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Commercial Electric (15 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7132-12-CE / 7132-12-CE | PD ID 3477949 (Qualified 2024-05-03) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (57.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.1 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Commercial Electric 7132-12-CE handle taller ceilings or walk-in tub steam?
Evaluate how Commercial Electric 7132-12-CE scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 57 sq ft | 1 CFM/sq ft @ 57.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 50 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.8 kWh/yr (~$1.41/yr) | 24.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 212.0 kWh/yr (~$33.92/yr) | 24.2 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Commercial Electric 7132-12-CE?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7105-08-L | 80 / 59.9 CFM | 1.1 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| Broan (Canada) EZ80C | 80 / 65.6 CFM | 1.1 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7141-80-G4 | 80 / 61.2 CFM | 1.1 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7141-80 | 80 / 62.9 CFM | 1.1 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Air King LEDAK80 | 80 / 70.3 CFM | 1.2 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
Is Commercial Electric 7132-12-CE sized right for your shower or tub room?
Check whether Commercial Electric 7132-12-CE clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
When does Commercial Electric 7132-12-CE fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Commercial Electric 7132-12-CE.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Recommended when: Moisture load fits 57.1 CFM net static output
- Target scenario: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Commercial Electric 7132-12-CE?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Commercial Electric 7132-12-CE.
Does running Commercial Electric 7132-12-CE continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Commercial Electric 7132-12-CE draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Commercial Electric 7132-12-CE pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric 7132-12-CE's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Commercial Electric 7132-12-CE?
Commercial Electric 7132-12-CE features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Commercial Electric 7132-12-CE's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric 7132-12-CE's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Commercial Electric 7132-12-CE code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Commercial Electric 7132-12-CE clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Commercial Electric 7132-12-CE?
Do not force Commercial Electric 7132-12-CE into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Commercial Electric 7132-12-CE retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Commercial Electric 7132-12-CE produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Commercial Electric 7132-12-CE disturb adjacent bedrooms during night use?
Acoustic measurement places Commercial Electric 7132-12-CE at 1.1 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)