Skip to main content
Grant Estimator

Fantech SMPL80L (484301) Exhaust Fan Specifications

ENERGY STAR PD #2507882 · Bathroom/Utility Room · Qualified 2023-05-19
Verified Specification Summary

Homeowners specifying Fantech SMPL80L (484301) gain 80 CFM at 0.1 in. w.g. (75 CFM at 0.25 in. w.g.) where it registers #357 of 607 in quietness (1.1 sones) and delivers 5.0 CFM/W efficacy, venting bathrooms up to 75 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech SMPL80L (484301) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 75 CFM
Noise @ 0.1"
1.1 sones (#357/607)
Efficacy Rank
5.0 CFM/W (#514/1,145)
Static Retention
93.8% @ 0.25"
Motor Draw
16.0 W (5.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech SMPL80L (484301) vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 75 CFM out of 80 CFM (93.8% retention, 6.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Fantech's 52-unit lineup, SMPL80L (484301) (series: bathfan Simple) carries PD #2507882 dating to 2023-05-19. Lighting kit: Yes. At 5.0 CFM/W (#514 of 1,145, top 45.2% of 1,145 rated models, more efficient than 54.8% of rated models, 0.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.0 watts, about 5.8 kWh/yr (~$0.93/yr at $0.16/kWh) for 1 hr/day shower timers or 140.2 kWh/yr (~$22.43/yr) continuously. Closest competing matches include HomeWerks Worldwide 7117-01-BN (80.0 CFM) and HomeWerks Worldwide 7117-01-WH (80.0 CFM).

What acoustic percentile does Fantech SMPL80L (484301) occupy among 1,145 bath blowers?

Inspect how Fantech SMPL80L (484301) positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.1 sone: 1.1 sones (62nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.1 sone: 1.1 sones (P62)

Which exterior damper path suits Fantech SMPL80L (484301) best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Fantech SMPL80L (484301) housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Fantech SMPL80L (484301) acoustic and static metrics stand?

Compare Fantech SMPL80L (484301) published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series SMPL80L (484301) / bathfan Simple PD ID 2507882 (Qualified 2023-05-19)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (75 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.1 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Fantech SMPL80L (484301) handle taller ceilings or walk-in tub steam?

Evaluate how Fantech SMPL80L (484301) scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Fantech SMPL80L (484301)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 75 sq ft1 CFM/sq ft @ 75 CFM
Tall Bath (9-ft Ceiling)Up to 66 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 25 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.8 kWh/yr (~$0.93/yr)16.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2140.2 kWh/yr (~$22.43/yr)16.0 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Fantech SMPL80L (484301)?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
HomeWerks Worldwide 7117-01-BN 80 / 65.4 CFM 1.1 sones (Same) 4.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-01-WH 80 / 65.4 CFM 1.1 sones (Same) 4.6 CFM/W 4 in. diameter
S&P PCLP80 80 / 68.3 CFM 1.2 sones (+0.10) 4.7 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80 80 / 62.9 CFM 1.1 sones (Same) 4.1 CFM/W 4 in. diameter
Panasonic FV-08VRE2 80 / 66.7 CFM 1.0 sones (-0.10) 4.3 CFM/W 4 in. diameter

Is Fantech SMPL80L (484301) sized right for your shower or tub room?

Check whether Fantech SMPL80L (484301) clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

What plumbing or duct constraints rule out Fantech SMPL80L (484301)?

Compare where Fantech SMPL80L (484301) excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 25 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 75 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Fantech SMPL80L (484301)?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Fantech SMPL80L (484301).

Can Fantech SMPL80L (484301) serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Fantech SMPL80L (484301) supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Fantech SMPL80L (484301) for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Fantech SMPL80L (484301) lacks adequate reserve.

How does Fantech SMPL80L (484301) handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Fantech SMPL80L (484301) yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Fantech SMPL80L (484301) quiet enough for a primary bedroom bathroom?

At 1.1 sones, Fantech SMPL80L (484301) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Fantech SMPL80L (484301) energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Fantech SMPL80L (484301) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech SMPL80L (484301)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech SMPL80L (484301)?

Fantech SMPL80L (484301) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech SMPL80L (484301)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech SMPL80L (484301)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories